ANUP5204 Aicure
Irradiation
27
8-3 Pattern Irradiation
If you need to change the UV intensity over time, you can do so automatically by registering a pattern
that changes the UV intensity and irradiation time.
There is a mode that allows you to select freely between four UV intensities; this mode
is available via external signals only. See 9-2. Operation via External Signals for details.
Registering a Pattern
You can register patterns of up to 10 steps. You can register up to 9 patterns, numbered 0 through 8.
For each step, you can set an irradiation time (timer value) and UV intensity.
Sample Pattern 1
・
Steps are executed in order, from 0 to 9.
・
At each step, irradiation is performed at the set UV intensity. After the set time has elapsed,
execution proceeds to the next step.
Sample Pattern 2
・
To end irradiation before a given step number, set the timer value of the step before the final step
to "0.0".
For example, say you want to perform irradiation in four steps, 0 to 3. You would then set the timer
value for step 4 to 0.0.
Warning