10. Replace Lamp Indicator Function
When the lamp lifetime approaches, this function informs you that it is time to replace the lamp. The
Aicure ANUP5204 maintains a count of the cumulative number of hours that the lamp has been on. 30
hours before the set number of hours, the "LAMP CHANGE" LED on the operation panel lights, and
the LAMP CHANGE external signal (pin 7) goes on. Please replace the lamp within 30 hours.
Setting the Lamp Replacement Time
If you are using the replace-lamp indicator function, set the lamp-replacement time. The factory
setting for lamp warranty time is 2,000 hours. If you need to change this value in accordance with the
lamp specifications, reset it.
After starting operation, do not change the setting unless you replace the lamp.
1
On the front panel, press the "LAMP HOUR" button. The
LED above the "LAMP HOUR" button lights, and the
current cumulative number of hours that the lamp has
been on appears in the display.
2
On the operation panel, press the "SET" button until you
hear a beep (at least 1 second). The LED above the
"LAMP HOUR" button flashes, and the lamp-replacement
alarm time appears in the display.
3
Press the up and down arrow buttons to change the value
(hours). Press the up arrow button to increment the value.
Press the down arrow button to decrement the value.
Press and hold one of the buttons to speed the rate of
increase/decrease.
The value can be set in a range of 1 to 5,000 hours, in
increments of 1 hour.
4
Press the "SET" button until you hear a beep (at least 1
second).
Resetting the Cumulative Lamp Use Time
When you replace the lamp with a new one, reset the cumulative lamp use time. If you do not reset
the time, then you will not be able to receive the correct notification of the lamp replacement time.
1
On the front panel, press the "LAMP HOUR" button. The
LED above the "LAMP HOUR" button lights, and the
current cumulative number of hours that the lamp has
been on appears in the display.
2
On the operation panel, press the "LAMP HOUR" and "SET"
buttons simultaneously until you hear a beep (at least 1
second). This resets the cumulative lamp use time to 0.
Warning