Installing the lens unit (optional)
Use a lens unit to increase the UV intensity by focusing the UV light.
1
Press the lens unit all the way into the light guide fiber
unit irradiation outlet.
2
Using a hexagonal wrench (1.5mm), tighten the two
hexagonal mounting screws.
Do not scratch the lens or touch it with your bare hands.
If the lens becomes soiled, wipe it clean with alcohol.
Installing the UV-blocking filter (optional)
Use a heat-ray blocking filter unit to reduce the temperature of the irradiation unit. This unit passes
through short-wavelength radiation (254 to 436 nm), and blocks heat rays greater than this.
Mount the heat-ray blocking filter before attaching the light guide fiber unit to the Aicure
main unit.
1
Screw the heat-ray blocking filter all the way onto the light
guide fiber unit irradiation inlet.
2
Press the light guide fiber unit all the way all the way into
the fiber-unit mounting inlet on the main unit, then lock it
in place with the bolt.
Warning
Warning