Aicure ANUP5204
Specifications
47
14. Specifications
Device Name
ANUP5204 (with pattern irradiation feature)
Input Power
100 to 24 V AC (90 to 264 V AC); dual 50/60 Hz; 280 V A
UV Lamp
Preset ANUPS204 200W mercury xenon lamp
Lamp lifetime: 3,000 hours (2000 hrs. guaranteed time: Min. 70% of
initial strength for horizontal lighting and min. 80% of initial strength for
vertical lighting.)
UV intensity
When measuring with 1-mm diam. sensor, UV control is off, and using
ANUP5051 fiber unit (5 mm diam. straight)
Irradiation
distance
15 mm
Average UV
intensity
2,300 mw/cm
2
(Guaranteed value 2000 mw/cm
2
)
UV
Autocontrol
This feature automatically compensates for deterioration of lamp
intensity to maintain stable UV intensity.
Even if the power is turned off midway through, the time is recorded,
and tracked.
Pattern
Irradiation
・
This feature allows you to perform irradiation with freely
programmed UV intensities and times as patterns (up to 10 steps) (9
patterns – pattern numbers 0 through 8 – can be set)
・
This feature also allows you to freely select from 4 preset UV
intensities via external signals (pattern number 9).
Setting Lock
This feature prevents values from changing. On the operation panel,
simultaneously press and hold the up and down arrow buttons for at
least three seconds to lock or release the settings.
Features
Counter
This feature automatically counts the number of times the shutter
opens. This can be used to count production volume or the like.
Replace Lamp Indicator
30 hours before the cumulative lamp use time reaches the lamp
replacement time, the "LAMP CHANGE" LED lights, and the user is
notified that it is time to replace the lamp (at the same time, the "LAMP
CHANGE" signal is output).
Shutter
Open/close manually or via timer
Minimum open/close time
1 sec open, 1 sec closed (2-sec cycle)
Timer open/close interval
1.0 to 999 seconds
Input
Shutter open/close (manual/timer), lamp on, UV adjuster open/close
External
Signal
Output
Lamp on, lamp stable, shutter open, shutter closed, lamp lifetime, error
Ambient temp. for use
10 to 40
o
C
Relative humidity
No greater than 80%, with no condensation
External dimensions
165 x 200 x 325 mm (LxHxD) (excluding protruding parts)
Main-unit weight
7.5 kg