ANUP5204 Aicure
Troubleshooting
45
13-2. If an Error Occurs
Error Warnings
When the Aicure ANUP5204 detects an error, it provides the following error warnings.
(1) "ERROR" LED on operation panel lights
(2) Alarm sounds
(3) Lamp turns off
(4) An error code appears in the operation-panel display (see next page)
(5) External control connector
LAMP STABLE signal (pin 3) off
ERROR signal (pin 5) on
Reset Error Status
Press and hold the "SET" button until you hear a beep (at least 1 second). The alarm buzzer stops.
Note, however, that the error display will not clear until the cause of the abnormality has been dealt
with, and the lamp will not come on.
See the following page for measures to take in the event of abnormalities. After taking the measures,
press the "SET" button again to clear the error display and end error status.
(1)
(4)
Press to reset