Chapter 1. Programming Site Data
20
DigitalFlow™ DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual (2-Channel)
1.6.5 Entering Setup Data
The signal limits and response times for the Model DF868 are specified via the
SETUP
submenu. While following the
programming instructions, refer to the menu map in Figure 12 on page 99. The following four submenus are included
in this section:
•
SIGNL
- set the parameters related to the transducer signal
•
AVRG
- specify the response of the meter to step changes
•
INIT
- initialize all parameters to default values.
•
ADVAN
- activates options for KV/SS, temperature vs. viscosity, Multi K factors, Mass Flow, Code Length and Active
Tw Measurement.
Table 14 on page 28 lists default values and limits for
SETUP
parameters. Remember to record all programmed data
in Appendix B,
Data Records
.
1.
To enter the
Channel PROGRAM
menu, press
[F1]
or
[F2] (depending on the desired channel) at the User
Program
prompt.
2.
Enter the
SETUP
submenu by pressing [
and
[F1]
at the
Channel PROGRAM
prompt.
1.6.5.1
The SIGNL Option
Use this option to set the limits for the incoming signal and other parameters affecting the transducer signal. For
example, the programmed signal strength low limit may be used to determine the trigger point for an alarm.
CAUTION!
The SIGNL default settings are suitable for most applications. Before changing any of these
parameters, consult the factory.
The signal options are different, depending on whether you have selected Transit-Time or TransFlection in the
ACTIV
submenu. Only after consulting the factory, complete the following steps to enter the signal parameters.
1.
Press
[F1]=SIGNL to enter the SIGNL submenu.
•
For Transit-Time mode, refer to
Transit-Time SIGNL Options
on the next page.
•
For TransFlection mode, refer to
TransFlection SIGNL Options
Содержание DigitalFlow DF868
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 10: ...Contents viii DigitalFlow DF868 Programming Manual 2 Channel...
Страница 104: ...Appendix A Menu Maps 96 DigitalFlow DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual 2 Channel...
Страница 118: ...Appendix B Data Records 110 DigitalFlow DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual 2 Channel...
Страница 150: ...Appendix E OPC Server 142 DigitalFlow DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual 2 Channel...
Страница 158: ...2 DigitalFlow DF868 Multipurpose Ultrasonic Liquid Flowmeter Programming Manual 2 Channel...
Страница 159: ......