Tel. 0039 030 6857073 - Fax 0039 030657079 [email protected] - www.palazzani.it
Pag. 49
OM3203_US
3.4. PLATFORM STARTING PROCEDURE
Especially after a period of inactivity, before starting the engine it is recommended to
check all the safety devices and controls.
Some of these controls can be fulfi lled with the machine off, other controls after the
stabilizers positioning. For the fi rst ones:
1) check the fuel level;
2) check the hydraulic oil level;
3) check the electrolyte level and batteries charge;
4) check the track condition;
5) check the stop buttons on the two control panels and on the main control panel
6) check the booms extension chains integrity and tension (the chains must remain ten-
se to the touch and not loosen during boom extension and retraction).
WARNING:
Don’t start the platform in case of any irregularity
3.5. USE WITH DIESEL ENGINE
The equipment has two sources of energy: one of these is autonomous and is genera-
ted by the diesel engine. It is used for the loading/unloading from the track or to travel
during a long transfer. It can be used for the aerial movements if the exhaust gas and
noise emissions are not dangerous for the workplace (closed environments, prohibition
of noises, etc ... ).
The diesel engine offers the advantage of greater speed of movements (for tracks and
arm) and the energy autonomy.
To work with this type of source, follow these instructions:
• Turn on the machine from the main panel (part 1 Fig. 3.1) in position 1 (oil and
battery lamps switch on)
• turn the key till the engine starts
• leave the engine running some minutes (at least 5 minutes in witnter temperatu-
res).
• if after some rounds the engine turns off, wait 20 seconds before start it again
because there is a safety protection to prevent start-ups close.
• during the aerial movements, the engine is calibrate on a fi xed speed, while du-
ring the travelling operations the tracks speed will increse if the selector on the
control panel is set on the hare symbol.
• to turn off the engine, press the “STOP” button on one of the control panels; but
remember to unlock it, otherwise the engine doesn’t switch on again.
• Also on the control panel on the ground is possible to turn on the engine from the
switch 10 of fi g. 3.4.
Содержание RAGNO TSJ 30.1
Страница 17: ...Tel 0039 030 6857073 Fax 0039 030657079 info palazzani it www palazzani it Pag 9 OM1202_US fig 1 3a ...
Страница 18: ...Tel 0039 030 6857073 Fax 0039 030657079 info palazzani it www palazzani it Pag 10 OM1202_US fig 1 4 ...
Страница 74: ...Tel 0039 030 6857073 Fax 0039 030657079 info palazzani it www palazzani it Pag 66 OM3203_US ...
Страница 80: ...Tel 0039 030 6857073 Fax 0039 030657079 info palazzani it www palazzani it Pag 72 OM3203_US Fig 3 19 ...