Error list TC161
16
Subject to change without notice
67
Error
nr.
Conditions
In- /
Output
Description Possible
Causes
40 Machine
Start
Packing cycle
Stop-Reset-Start
B17
Time for moving out ejectors exceeded
8. Package jam in front of the ejector
9. Air pressure
10. Cylinder, cylinder switch
11. Sensor B17 defective
12. Input IN01.13 problem
13. Throttle D1 defective
14. Elevation table's lowest position set too low
41 Machine
Start
Normal position
B16
B1
Machine goes into normal position and table does not
go up
6. Air pressure
7. Cylinder, cylinder switch ejector
8. Sensor B16 defective or wrongly adjusted
9. Sensor B1 defective
10. Input IN03.1 problem
42 Machine
Start
Band End
B13
After "band end" has been shown on the display, the
machine switches off after the pre-programmed
number of cycles has been reached
5. Change tapes
6. Change quantity of cycles with code 127
7. Cable defective
8. Input IN03.4 problem
48
B16
Elevation table moves down
B16 is not covered
4. Package jam in front of the ejector
5. Air pressure
6. Cylinder, cylinder switch
49
B16
B1
Elevation table moves up
B16 or B1 are not covered
4. Package jam in front of the ejector
5. Air pressure
6. Cylinder, cylinder switch