Code list TC161
14
Subject to change without notice
55
Code-
Nr.
Password
protected
Set
value
Limit
-
Limit
+
Unit Title
Description
116
yes
50
0
Direction counter 5
In stream delivery mode, this is the maximum the belts move the
sheet forward as it arrives. The distance is calculated from the
calibrated value. Standard value is 50% of the calibrated sheet
length.
117
yes
50
0
200
in % of the
sheet length
Max. distance
Maximum distance of the deflector before a reaction has to occur.
118
yes
259
0
mm
Direction counter 6
In stream delivery mode, the start is triggered by photocells
B8/B9/B11. The transport belts start after this value has elapsed
119 no
0
1
2
3
0 3
Language
1
Language 2
Language 3
Language 4
German
English
Dutch
120
no
0
Photocell on the sheet run 0=all, 1=B8, 2=B11, 3=B9
121
yes
2000
1000
5000
ms
Delay 16
Welding time monitoring. If the heating dies are heated for a long
time, the machine stops with error 18.
122
no
20
20
5000
ms
Delay 6
After reaching the pre-selected batch piece value, the elevation
table moves into the intermediate position and stops after photocell
B18 is released. Photocell B18 must remain free for at least this
period of time before the elevation table stops.
123
no
300
0
10000
ms
Delay 7
After reaching the intermediate position, the elevation table moves
upwards until press sensor B5 responds. This is the maximum
value during which it moves up. After this value, the elevation table
is stopped and the welding process is triggered independently from
B5.
124
no
1500
ms
Delay 8
Only in connection with the option "Batch level compensator".
Usually, the batch level gates are set so that they retract when they
reach the intermediate position. This retraction can be delayed by
increasing this value.
125
yes
1500
ms
Delay 9
After activation, the pressing guides must be extended at the latest
after this length of time (B3). If not, the machine will stop with Error
16.
126
no
1
Running out of banding, the machine stops with Error 42 (see also
code 127).
Содержание 102-13
Страница 2: ......
Страница 6: ...6 Subject to change without notice ...
Страница 43: ...Pneumatics 5 Subject to change without notice 43 ...
Страница 68: ...0 68 Änderungen vorbehalten ...