Error list TC166
15
Subject to change without notice
61
Error
nr.
Conditions
In- /
Output
Description Possible
Causes
30 Machine
Start
Packing cycle
B14
Elevation table moves to starting position and takes too
long
1. Elevation table system fault (Motor, FRQ, etc.)
2. Parcel between pressing bars & elevation table
3. Sensors B14 or B20 defective
4. Input IN01.6 problem (B14)
5.
Elevation table knocks against the jogging plates
(bent)
31 Machine
Start
Packing cycle
B2
Time for extending welding die exceeded
welding die
moves to working position
1. Paper between the welding dies
2. Air pressure
3. Sensor B2 defective or wrongly adjusted
4.
Input IN03.2 problem
32 Machine
Start
Packing cycle
B1
Time for retacting welding die exceeded
welding die
moves to normal position
1. Defective cylinder
2. Air pressure
3. Obstacle
4. Sensor
B1
defective or wrongly adjusted
5.
Input IN03.1
problem
6. Linear bearing defective
34 Machine
Start
Open Guard
Drives turn at too high a speed during jogging
operation
1. Frequency converter defective
2. Tacho defective
3. Frequency converter set to wrong parameters
35
Destacking without
counter release
B12
Sensor B12 do not aware the product
batch counter does not count,
destacking sensor covered.
1. Sensor
B12
wrongly
adjusted or
defective
37
B41
Frequency converter pressing drive has switched off
1. Fault with frequency converter A13
2. Protective motor switch Q3 has switched off
38
B42
Frequency converter belt drive has switched off
1. Fault with frequency converter A14
2. Protective motor switch Q3 has switched off
39
B43
Frequency converter elevator table drive has switched
off
1. Fault with frequency converter A15
2. Protective motor switch Q3 has switched off