13
Code list TC166
52
Subject to change without notice
Code
nr.
Password
protected
Set
value
Unit Title
Description
119 no 0
1
2
3
Language
1
Language 2
Language 3
Language 4
German
German
English
Dutch
120
no
0
Photocell counter lane (B8, B9, B11), 0 = all, 1, 2 or 3
121
yes
2000
1/1000 sec
Delay 16
Welding protection
122
no
2
1/100 sec
Delay 6
After reaching the pre-selected batch piece value, the elevation table moves into the
intermediate position and stops after photocell B18 is released. Photocell B18 must remain
free for at least this period of time before the elevation table stops.
123 no 50
1/100 sec
Delay 7
After reaching the intermediate position, the elevation table moves upwards until press
sensor B5 responds. This is the maximum value during which it moves up. After this value,
the elevation table is stopped and the welding process is triggered independently from B5.
124
no
0
1/100 sec
Delay 8
Only in connection with the option "Batch level compensator". Usually, the batch level
gates are set so that they retract when they reach the intermediate position. This retraction
can be delayed by increasing this value.
125
yes
100
1/100 sec
Delay 9
After activation, the pressing guides must be extended at the latest after this length of time
(B3). If not, the machine will stop with Error 16.
126
no
1
Running out of banding, the machine stops with Error 42 (see also code 127).
127
no
200
cycles
Cycle selection after display of end of banding until machine stops with Error 42
128
no
0
each
Counter
Only in connection with the option "Batch level compensator". After reaching this value, the
batch level gates are set by the batch counter.
129
no
min 1
Flashing rate of signal indicator
130 no 0
1
not active
active
Operation of the banding delivery without package lift
Operation of the banding delivery with package lift.
131 no 1
0
left
right
Operation of the package lift on the operator side
Operation of the package lift on the control box side
132 no
1,2,3,4,5
o. 6
Packing cycle
The package lift will start after thiese cycles have elapsed
133
yes
50
1/100 sec
Delay 10
After ejecting the banded stacks, the side loader will start after this amount of time has
elapsed.
134
yes
50
1/100 sec
Delay 11
After conveying the banded stacks to the package lift using the side loader, the lift table will
start after this value has elapsed.