14
Code list TC161
56
Subject to change without notice
Code-
Nr.
Password
protected
Set
value
Limit
-
Limit
+
Unit Title
Description
127
no 1 Zyklen
Cycle
selection
after
display of end of banding until machine stops
with Error 42
128
no
0
Stück
Counter
Only in connection with the option "Batch level compensator". After
reaching this value, the batch level gates are set by the batch
counter.
129
no
1000
10000
100
ms
Flashing rate of signal indicator
130 no
0
1
nicht
aktiv
aktiv
Operation of the banding delivery without package lift
Operation of the banding delivery with package lift.
131 no
1
0
links
rechts
Operation of the package lift on the operator side
Operation of the package lift on the control box side
132 no
1,2,3,4,5
o. 6
Packing cycle
The package lift will start after these cycles have elapsed
133
yes
500
500
ms
Delay 10
After ejecting the banded stacks, the side loader will start after this
amount of time has elapsed.
134
yes
500
500
ms
Delay 11
After conveying the banded stacks to the package lift using the side
loader, the lift table will start after this value has elapsed.
136
yes
100
This time elapses after start is pressed. The machine starts.
138
yes
15
m/min
Monitoring
of
set-up
speed
For press drive
139
yes
8 m/min
Monitoring
of
set-up
speed
For band drive
140
Display for actual sheet length
141
mm
Display for the result of the measurement of the last bad sheets.
142
m/min
Display for the speed of the transport belts
143
date
Last
software
change
145
cycle
Display for cycles until machine stops with Error 42 running out of
banding.
150 yes
0
1
not
active
active
By activating Total Reset, all memory will be deleted. All variable
values will be deleted. All code values will return to basic setup
151
yes
PW2
0
Erase
RAM
152
yes PW2
0
Erase RAM and switch over to programming mode.