Error list TC161
16
Subject to change without notice
65
Error
nr.
Conditions
In- /
Output
Description Possible
Causes
22
B30
Guard open
9. BA guard open
10. Folding machine guard open
11. Lower banding door of the BA open
12. Cover under the press open/released
13. Cover in front of the press open
14. Cover after the press open
15. Input IN02.5 or input IN02.6 problem
16.
Wrong adapter used to connect with MBO folding
machine with 18-pin plug
23
Emergency-Off folding machine
3. Error message from the folding machine
4. Input IN02.13 problem
24
Emergency-Off button S1
3.
Emergency-Off button on BA 700 pressed
or
defective
4. Input IN02.1 problem
25
Emergency-Off protective motor switch Q4
2. Protective motor switch on the jogging drive has
switched off
26 Emergency-Off
K6
Emergency-Off
contactor K6 malfunction
5. Emergency-Off contactor K6 does not fall away
6. Fuses F10 or F11 defective
7. Power unit defective
8.
One of the sensor cables defective
27
Guard open
K33
Guard contactor K33 malfunction
1. Guard contactor K33 does not fall away
28
B45
Temperature switch-off of the motors
5. Temperature switch in the motors
Press drive motor too hot
Belt drive motor too hot
Elevation table drive motor too hot
6. Output 02.10 defective
7. Input IN02.11 problem
8.
Code 123>50 adjusted
29 Machine
Start
Packing cycle
Elevation Table down
B15
Elevation table moves to delivery position and takes
too long
7. There is material under the elevation table
8. Elevation table down does not function
9. Sensor B15 or B21 defective
10. Elevation table motor defective
11. Frequency converter
12. Input IN01.7 problem (B15)
Содержание 102-13