Code list TC166
13
Subject to change without notice
53
Code
nr.
Password
protected
Set
value
Unit Title
Description
135
136 no
Set-up
time
137 yes 0
1
not active
active
Cycle time reduction - Welding heads starts as the same time as elevation table "up".
140
Display for actual sheet length
141
Display for the result of the measurement of the last bad sheets.
142
m/min
Display for the speed of the transport belts
143
date
Last software change
144
yes
1/1000 sec
Delay 12
Welding time monitoring - if the heating dies are heated for a long time, the machine is
stopped with Error 18
145
no
Display for cycles until machine stops with Error 42 running out of banding.
150 yes 0
1
not active
active
By activating Total Reset, all memory will be deleted. All variable values will be deleted. All
code values will return to basic setup
170 no 0
1
Operating mode paper banding
Operating mode plastic PE-banding
171
no
40
1/100 sec
Delay 13
Heating time for PE-banding
172
no
3
1/100 sec
Delay 14
Cutting time for PE-banding
173
no
100
1/100 sec
Delay 15
Cooling time for PE-banding
175
yes
1
Delay 17
Starting delay for small-package facility
176
yes
1
Delay 18
Switch-off delay for small-package facility
203
no
Input display - Inputs can be checked during operation using cursor up / cursor down keys
204
no
Output display - Outputs can be checked during operation using cursor up / cursor down
keys