Sensor Technology
4
Subject to change without notice
31
Sensor Position/Name
Adjustment
B14
Elevation table upper final position As it moves upwards, the elevation table must
stop in good time so that
distance A is a
minimum of 2 mm and a maximum of 4mm.
Distance
C
between sensor B14 and the
elevation table should be
0,5mm
.
B20
Change-over to slow speed when
travelling to the upper final position
The height of sensor B20 is adjusted together
with sensor B14. Distance
C
between Sensor
B20 and the elevation table should be
0,5mm.
B15
Elevation table lower final position As it moves downwards, the elevation table
must stop in good time so that distance
B
(upper edge of elevation table to upper edge of
base plate) is
+/- 1mm
B21
Change-over to slow speed when
travelling to the lower final position
The height of sensor B21 is adjusted together
with sensor B15. Distance
C
between sensor
B21 and elevation table should be
0,5mm.
Distance A
Distance C
Distance B
Base plate