AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 179 of 274
Command Syntax
[SOURce:]VOLTage:DC#:LIMit:MAXimum
Description
Sets upper user limit for DC voltage programming for phase #. If # is
omitted, sets all available phases to value specified. User limits must
fall within actual hardware limits of the power source. Also, MIN limit
must be less than MAX limit.
Parameters
-425.0 – 425.0
Parameter Format
<nr2>
Example
VOLT:LIM:DC1:MAX 270.0
Query Format
[SOURce:]VOLTage:DC#:LIMit:MAXimum?
Returned Data Format
<nr2>
Query Example
VOLT:LIM:DC:MAX?
-425.000
Query Format
[SOURce:]VOLTage:DC#:LIMit:RANGe?
Description
This query returns both upper and lower user limits for DC voltage
programming.
Returned Data Format
<nr2>,<nr2>
Query Example
VOLT:DC1:LIM:RANG?
-425.0000,425.0000
Query Format
[SOURce:]VOLTage:DC#:LIMit:ALLOwed:RANGe?
Description
This query returns the available DC programming range -
regardless of
any user limits
- that is valid for the selected voltage range.
RANG? = 1 (HIGH) If HIGH voltage range is set, the returned values are -425 and 425
RANG? = 0 (LOW) If LOW voltage range is set, the returned values are -212.5 and 212.5
Returned Data Format
<nr2>,<nr2>
Query Example
VOLT:DC1:LIM:RANG?
-212.5,212.5
Содержание 3120AFX