6.4.7
Available Waveforms
The AFX Series® is supplied with 16 pre-
loaded waveforms but can hold a total of
128. The default content of the first 16
registers is shown in the table below. Also
shown are the waveform number names
and the waveform description each
waveform.
For waveforms with high harmonic
content – e.g. sharp transition or fast edges – the smoothing filter feature can be used to
smooth out these high frequency event to reduce over/undershoot as needed. The value
entered indicates the number of waveform data points that will be averaged to obtain a
smoother wave shape. Preview of the resulting smoothed wave form is shown on the LCD
screen.
Name
Description
Image
Notes
1
SINE
Standard sine wave. No harmonic
content. This is also the default selected
waveform at power on unless a power-
on setup is recalled.
Note: Waveform 1 is fixed and CANNOT
be changed!
2
CLIPPED THD 1%
Clipped sine with 1% total harmonic
voltage distortion due to flat topping of
sinewave peaks.
3
CLIPPED THD 2%
Clipped sine with 2% total harmonic
voltage distortion due to flat topping of
sinewave peaks.
4
CLIPPED THD 5%
Clipped sine with 5% total harmonic
voltage distortion due to flat topping of
sinewave peaks.
5
CLIPPED THD 10%
Clipped sine with 10% total harmonic
voltage distortion due to flat topping of
sinewave peaks.
Содержание 3120AFX