Query Format
[SOURce:]VOLTage[:AC]#:SATuration[:LIMit]?
Description
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur. Saturation limits are determined in the
maximum peak voltage capability of the AC+DC components at the
output of the power source. For the AFX Series®, these limits are -425
and +425V. The VOLT:AC1:SAT? returns the max. RMS of a sine wave
that may be programmed based on the programmed DC component.
Maximum allowable values are:
Maximum positive peak voltage:
V_peak_max = V_AC_pe V_DC
Minimum negative peak voltage:
V_peak_min = V_AC_pe V_DC
For a sinusoidal AC waveform, these limits are:
Vrms_sat = (
425
– Vdc) / 1.4142
Vrms_sat = (
-425
+ Vdc) / 1.4142
Examples
V_DC = 0
425 = 1.41 *
300
+ 0 (
V_AC_rms_sat = 300
)
V_DC = 100
425 = 1.41 *
229
+ 100 (
V_AC_rms_sat = 229
)
V_DC = 425
425 = 1.41 *
0
+ 425 (
V_AC_rms_sat = 0
)
Returned Data Format
<nr2>
Query Example
SOUR:VOLT:AC3:SAT:LIM?
300.5204
Command Syntax
[SOURce:]VOLTage[:AC]:INITial
Description
This command is equivalent to the “[SOURce:]INITial <n>” command
but applies only to the AC1, AC2 and AC3 parameters.
VOLT:INIT? = ON Set points of the unit at power on will be the last set after power off.
The set points affected by this command are:
- Voltage AC1
- Voltage AC2
- Voltage AC3
VOLT:INIT? = OFF Set points of the unit at power on will have a default value of:
- Voltage AC1 = 0V
- Voltage AC2 = 0V
- Voltage AC3 = 0V
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
VOLT:AC:INIT OFF
Query Format
[SOURce:]VOLTage[:AC]:INITial?
Returned Data Format
<b>
Query Example
VOLT:AC:INIT?
0