8.7.7
Waveform Programming Commands
Waveform Storage
The AFX Series® offers full arbitrary waveform programming capability in addition to the
standard waveforms that are provided. A total of 16 waveform registers are available. The
default content of these registers is shown in the table below. Also shown are the waveform
number names and the waveform description each waveform.
Name
Description
Image
Notes
1
SINE
Standard sine wave. No
harmonic content. This is
also the default selected
waveform at power on
unless a power-on setup is
recalled.
2
CLIPPED THD 1%
Clipped sine with 1% total
harmonic voltage distortion
due to flat topping of
sinewave peaks.
3
CLIPPED THD 2%
Clipped sine with 2% total
harmonic voltage distortion
due to flat topping of
sinewave peaks.
4
CLIPPED THD 5%
Clipped sine with 5% total
harmonic voltage distortion
due to flat topping of
sinewave peaks.
5
CLIPPED THD 10%
Clipped sine with 10% total
harmonic voltage distortion
due to flat topping of
sinewave peaks.
6
SQUARE LF
Square wave. Consists of
fundamental and all odd
harmonics. The LF (low
frequency) version is
recommended for use below
100Hz.
Содержание 3120AFX