AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 214 of 274
Command Syntax
SYSTem:REMote:ACCESS
Description
Sets remote access permission.
Parameters
<0 | DISABLED | 1 | ENABLED>
Parameter Format
<b>
Example
SYST:REM:ACCESS 1
Query Format
SYSTem:REMote:ACCESS?
Returned Data Format
<cr>
Query Example
SYST:REM:ACCESS?
Enabled
Query Format
SYSTem:REMote:ACCESS:CATalog?
Description
This command returns the status of the enabled functions on the
power source.
Returned Data Format
<cr>,…,<cr>
Query Example
SYST:REM:ACCESS:CAT?
All,Disabled,Webpage,Disabled,LAN,Disabled,LXI,Disabled,Telnet,
Disabled,USB-CDC,Disabled,Serial,Disabled
Command Syntax
SYSTem:REMote:ACCESS:REQuest
Description
This commands results in a pop up dialog on the front panel display
requesting the local user to ACCEPT. Confirms presence of a person at
the location of the instrument.
Parameters
Alias name. (This argument is optional)
Parameter Format
<cr>
Example
SYSTem:REMote:ACCESS:REQuest
Query Format
SYSTem:REMote:ACCESS?
Returned Data Format
<cr>
Example
SYSTem:REMote:ACCESS?
Enabled
Command Syntax
SYSTem:REMote:ACCESS:LOGIN
Description
This command uses a password as an argument to request access to
the instrument. The password can be set on the front panel or using
the
SYSTem:REMote:PASSword
command
Parameters
Password
Parameter Format
<nr1>
Example
SYSTem:REMote:ACCESS:LOGIN 1234
Query Format
SYSTem:REMote:ACCESS?
Returned Data Format
<cr>
Example
SYSTem:REMote:ACCESS?
Enabled
Содержание 3120AFX