AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 163 of 274
Command Syntax
PROGram[:SELected]:EXECute [<nr1> [,<cr>]
Description
This command executes the selected program (default) or the program
number passed as the first parameter.
Parameters
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter Format
[<nr1> [,<cr>]
Example
PROG:EXEC 2
Query Format
PROGram[:SELected]:EXECute ?
Description
The query format returns the number of the program that is in effect.
Parameter Format
<nr1>
Example
PROG:EXEC?
23
Command Syntax
PROGram:EXECute:TRANS [<nr1> [,<cr>]
Description
This command executes the selected program’s (default) transient
table or the program number passed as the first parameter.
Parameters
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter Format
[<nr1> [,<cr>]
Example
PROG:EXEC:TRANS 2
Command Syntax
PROGram:EXECute:TRANS:RESET
Description
This command serves the same purpose as the “PROGram:TRANsient
STOP” command. See next.
This command resets the active transient execution. This command is
included to support UPC compatibility mode although it is not
documented in the UPC manual. Not recommended for new programs.
Parameters
None
Parameter Format
n/a
Example
PROG:EXEC:TRANS:RESET