AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 172 of 274
Command Syntax
[SOURce:]FORM <nr1>
Description
Set phase mode or FORM. Allowable arguments are 1, 2 or 3.
Parameters
< 1 | 2 | 3 >
Parameter Format
<nr1>
Example
FORM 3
Query Format
[SOURce:]FORM?
Returned Data Format
<nr1>
Query Example
FORM?
3
Command Syntax
[SOURce:]COUPLing <cr>
Description
Selects the output coupling mode. On AFX Series®, this command only
accepts DIRECT as a setting.
Parameters
< DIRECT >
Parameter Format
<cr>
Example
COUPL DIRECT
Query Format
[SOURce:]COUPLing?
Returned Data Format
<cr>
Query Example
COUPL?
DIRECT
Command Syntax
[SOURce:]XFMRRATIO <nr2>
Description
Set the transformer ratio when using an optional output transformer.
The ratio setting allows the user to program the actual desired output
voltage.
Parameters
< 0.5, 1.0, 1.5, 2.0, 2.5 >
Parameter Format
<nr2>
Example
XFMRRATIO 2.0
Query Format
[SOURce:]XFMRRATIO?
Returned Data Format
<nr2>
Query Example
XFMRRATIO?
1.000000
Содержание 3120AFX