AFX SERIES® OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 22 of 274
4.3
AC Output Mode
AC OUTPUT
Voltage
AC Range
1
0 - 300 V L-N rms / 0 - 520V L-L rms, no VA or F restrictions
0 - 312 V L-N rms / 0 – 540V L-L rms, see Note 1
Programming Resolution
0.1 V
Accuracy
± 0.25% F.S.3
Waveforms
Sine wave, Clipped, Square, Triangle, Saw tooth, Arbitrary
Max. No. of waveforms: 128
DC Offset
< 20 mV
Harmonic Distortion
2
(Vthd)
(full, Resistive Load)
< 0.5% 15Hz – 400Hz, < 1.0% 400Hz-1000Hz, < 1.5% > 1000Hz
See V THD Chart at bottom of page
Output Noise (DC – 300 kHz)
< 150 mV rms
Load Regulation
± 0.02% (CSC Mode on)
Line Regulation
± 0.1% for 10% Line Change
External Voltage Sense
External Sense, max. voltage drop 5% FS.
Isolation
550 Vac
Frequency
Range
15.00 – 1200.0 Hz
Programming Resolution
3
0.01 Hz
Accuracy
± 0.01%
Current Limit
Range
4
See model tables, Figure 4-3 and Figure 4-5. Values shown are supported for any
period of time.
Current Overload
Available 30% Current overload for up to 2.0 seconds when enabled. See Figure
Crest Factor
2.5:1 @ 41.67 to 6.3:1 @ 16.67 (10
4
Apk / phase for 3150AFX)
Programming Resolution
0.01 A rms
Accuracy
± 0.5% F.S.
Modes
Constant Current Mode or Output Trip
Phase Angles (3 Phase Models)
Phase Offsets
5
A = 0°, B = 240°, C = 120° (programmable)
Accuracy
± 0.35°
Phase Rotation
1
in 3 Phase mode
(default)
A, B, C = 0°, 120°, 240° (L1, L2, L3)
Consistent with Pacific Power UPC Controller products. Phase rotation can be
configured to default to 0°, 240°, 120° if desired.
Note 1:
Extended operation to 312V L-N / 540V L-L is supported in Three and Split Phase mode up to 3.3kVA per phase
for frequency range 45Hz ~ 100Hz. Requires front panel firmware v3.4 or higher.
Note 2:
Refer to Figure 4-1, “
Output Voltage distortion into full R Load as
” on next
page.
Note 3:
FREQUENCY PROGRAM RESOLUTION FOR EXPORT MODELS (-4LE, -2LE):
Per U.S.A. Bureau of Industry and Security, ECCN 3A225, frequency control is limited to no better than 0.2% at
frequencies of 600 Hz. or more for unrestricted export products. To meet that requirement, frequency
programming in all -2LE and -4LE AFX models has three resolution ranges which round the frequency to the
nearest increment, as defined in the table below.
Frequency Resolution for Export Models
Range
Resolution
15.00 - 99.99 Hz
0.01 Hz
100-599.9 Hz
0.1 Hz
600 - 999 Hz
2.0 Hz
1000 - 1200 Hz
5.0 Hz
Содержание 3120AFX