MEASURE FIBER LENGTH
TEST PROCEDURES
25
CERT MODE
Optical Source
WaveSource Pro
AUTO
PORT
MOD
CW
Once the length measurement is complete, or was entered manually, the meter will return to the
test results screen with the length shown. At this time, disconnect the test cables from the link.
SIDE A
SIDE B
3
1
2
3
1
2
Loopback cable
at far end
completes the
loop for length
measurement
TEST
MANUAL
BACK
To test the fiber length, attach
the meter to the fibers as
shown or enter length manually.
CERT
FIBER#1
ACME CORP / HQ WEST
M=MC R=WA10
Length:
100m WAVE:
EIA/TIA 568C.3 CON: 2
INDOOR SM SPL: 2
1310
ENTER
--.--
----nm
by
dB
dB
SAVE
TEST
LEN
WAVE
These cables are no longer
required for testing and
can be set aside.
NOTE: the source is not used
during length measurement.
The Length measurement
will appear in the Length
field.
MC
WA10
NOTE: as an option, the fiber length may be entered manually
instead of connecting the meter and loopback cable to the link
under test.
To enter the fiber length in meters manually, press MANUAL. For example,
if the fiber length is 100 meters, enter the number ‘100’.
When the number has been entered, press DONE to return to the test
results screen.
Enter fiber length in meters:
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
0123456789 : ; <
<--
SHIFT
SPACE
DONE
Use arrows to highlight letter
then press the enter key. Tap
the power button to abort.