SET REFERENCE
TEST PROCEDURES
20
CERT MODE
This slide explains testing the additional test cable. Press YES to continue.
Optical Source
WaveSource Pro
AUTO
PORT
MOD
CW
You should measure your test
cable loss before testing.
Do you wish to do it now?
042
Checking additional test cable
(dotted line)
The additional test cable is
used to connect the optical
power meter to the link
under test, but is not used
for setting a reference.
Therefore, this test cable
should be checked prior to
testing to ensure it does
not introduce excessive
loss into the final optical
loss measurement.
Connect a mating sleeve to the end of each reference cable, then plug an additional test cable
as shown. Press any key on the meter to proceed.
Optical Source
WaveSource Pro
AUTO
PORT
MOD
CW
Using your test reference
cables, please connect the meter
and injector as shown and
press any key to proceed.