TEST PROCEDURES
PATCH CABLE VERIFICATION
OPM MODE
Check patch cables before testing to determine if they are okay to use.
NOTE: when using a F7L (Fiber OWL 7 LITE) power meter, a separate light source is required for checking patch cables.
Press MENU > OPERATIONS MENU > CONFIGURE SOURCE
NOTE: the Fiber OWL 7 must be capable of testing that type of fiber; i.e. singlemode and/or multimode. See table below
for a list of source settings.
If using CW (continuous wave) mode, choose one of the available wavelengths.
If using AUTO mode, both available wavelengths will be used.
Once all the settings have been
set, press EXIT to return to the
OPERATIONS MENU, then
re-ENTER OPM MODE.
SAVE
QUIT
HELP
SM
CW
1310
SOURCE SETTINGS
PORT:
MODE:
WAVE:
(nm)
Connect a patch cable between the OPM port and the source port on the Fiber OWL 7.
Make sure the UNITS are set to dBm.
NOTE: the Fiber OWL 7 must be capable of testing that type of fiber; i.e. singlemode and/or multimode.
LEN
OPM
Length:
0m WAVE:
1310
ENTER
LOW
1310nm
dBm
WAVE