Operation using the OP
X
-
2
A
−59−
What happens when the
key is pressed while the edit lock function is enabled
While the edit lock function is enabled, you cannot move to any lower level
from the top screen of the copy mode. Pressing the
key will generate
an error, and “LocK-Err” will be shown. Be sure to cancel the edit lock function
before pressing the
key. Refer to p.51 for the procedure to cancel the
edit lock function.
Note
•
If the
key is pressed while processing the memory of the
NETC01-M3
via MECHATROLINK-
Ⅲ
communication, the screen cannot move to the lower level from the top screen and "mEm-busy" is
displayed. Be sure to wait until the memory processing is completed, before pressing the
key.
•
When a system parameter has been changed, the new parameter will become effective after the
power is cycled. When system parameters were changed by downloading, cycle the
NETC01-M3
power.
•
Do not turn off the
NETC01-M3
power while the download is still in progress (=while the display is
blinking). Doing so may damage the data.
Error of the copy mode
If an error occurs in download or verification, the error code will blink on the display.
At this time, the processing will not be executed and the display will return to the top screen.
Blinking display
Description
Action
There is a discrepancy between
the selected product series and the
data being processed.
•
Check the product series.
•
Check the data bank number on the
OPX-2A
.
An error occurred while processing.
Execute the processing again. If the
same error occurs, the parameters
saved in the
OPX-2A
may have
damaged. Upload and set the
parameters of the
OPX-2A
again.
The specified data bank number
does not contain data.
Check the data bank number.
An error occurred while parameter
was being downloaded.
Perform download again.