Operation using the OP
X
-
2
A
−54−
13.6 Screen transitions
Monitor mode
Top screen of the
copy mode
Download
Data bank selection 0
Data bank selection 3
Data bank selection 0
Data bank selection 3
Data bank selection 0
Data bank selection 3
Data bank selection 2
Data bank selection 1
Upload
Verification
Parameter initialization
Verification result:
Matched
Verification result:
Unmatched
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Data bank selection 2
Data bank selection 1
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Processing is
in progress
(blinking display)
Data bank selection 2
Data bank selection 1
Initialize all parameters
System parameter
Connection
(address number 0)
Enable
Disable
Connection
(address number 1)
Connection
(address number 2)
Connection
(address number 15)
RS-485 communication
scan time
RS-485 communication
status
Address number 0 to 7
Address number 8 to15
Present alarm
Present warning
Top screen of the
parameter mode
Top screen of the
monitor mode
Top screen at power ON
Alarm record 1 (latest)
Alarm record 10 (oldest)
Processing is in progress
(blinking display)
Processing is in progress
(blinking display)
Processing is in progress
(blinking display)
Alarm reset
Clear alarm records
Warning record 1 (latest)
Warning record 10 (oldest)
Clear warning records
key to return to the previous level.
In the lower level except the top screen, press the
- - - Broken line indicates that data writing cannot be executed when internal
processing is in progress via MECHATROLINK-
Ⅲ
communication.
“mEm-bUSy" is displayed even when the
key is pressed.
Note
•
For the parameter mode and copy mode, if the
key is pressed while processing the memory of the
NETC01-M3
via MECHATROLINK-
Ⅲ
communication, the screen cannot move to the lower level from the top screen
and "mEm-busy" is displayed. Be sure to wait until the memory processing is completed, before pressing the
key.
•
The following limitations are present while the edit lock function is enabled.
•
Parameter mode, copy mode: Although they are displayed on the screen, they are unable to operate.
•
Clearing the alarm and warning records: They are not displayed on the screen.