MOBILE WELDER OC PLUS
ENGLISH
ORBITALUM TOOLS GmbH
, D-78224 Singen www.orbitalum.com
123
8.1.6
Settings
8.1.6.1
System adjustments
Adjustments can be made at the system level in the system settings.
2
4
1
3
5
Illustration: System adjustments, upper region of menu
NO.
DESIGNATION
SYSTEM ADJUSTMENTS OPTIONS
1
"Flow Sensor"
ON/OFF
The welding gas sensor and thus welding gas monitoring can be temporarily
deactivated via the "Flow Sensor ON/OFF" function. This can be useful, for
example, when the gas sensor is defective and work must be continued tem-
porarily.
"Flow Sensor": ON
Welding gas monitoring active
"Flow Sensor": OFF
Welding gas monitoring deactivated
CAUTION! When the welding gas sensor is deactivated, the flow of
welding gas from the power supply is not actively monitored! There-
fore, increased operator attention is required during continued use of
the power supply. The flow of welding gas and the quantity must be
monitored by the operator himself! Defective sensors must be replaced
as soon as possible.
NOTICE! For safety reasons, the function is reset to gas sensor "ON"
each time the power supply is restarted
.
Содержание MOBILE WELDER OC PLUS
Страница 8: ...ENGLISH MOBILE WELDER OC PLUS 8 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Страница 20: ...ENGLISH MOBILE WELDER OC PLUS 20 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Страница 177: ...MOBILE WELDER OC PLUS ENGLISH ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com 177 ...
Страница 200: ...SPARE PARTS MOBILE WELDER OC PLUS 200 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Страница 204: ......