MOBILE WELDER OC PLUS
ENGLISH
ORBITALUM TOOLS GmbH
, D-78224 Singen www.orbitalum.com
65
NO.
DESIGNATION
FUNCTION
4
"Adjust Program" menu
button
Opens the "Adjust Program" menu, where welding parameters and
segments of the currently loaded welding procedure can be adjusted.
For detailed information, see the chapter
5
"TIG Manual Weld
Mode" menu button"
Opens a user interface adapted to manual welding.
For detailed information, see the chapter
6
"Logout" menu but-
ton
Takes you to the logout screen, where it is possible to switch be-
tween user levels and change passwords.
For detailed information, see the chapter
7
"System Settings" menu
button
Opens the "System Settings" menu, where system-, service- and
weld procedure-relevant settings can be made and system-relevant
information is displayed. In addition, system updates and activation of
optional software can be performed.
For detailed information, see the chapter
8
"Weld Mode" softkey
Opens the "Weld Mode" menu, where the welding torch can be con-
trolled, welding parameters adjusted and the welding process started.
For detailed information, see the chapter
9
"Test Mode" softkey
Opens the "Test Mode" menu, where the welding torch can be con-
trolled manually, welding parameters can be adjusted and a simula-
tion without arcing can be started in order to test all process-relevant
functions before welding begins.
For detailed information see the chapter
10
"Save" softkey
Saves newly created or modified welding procedures. If no welding
parameters for the currently active welding procedure have been
changed, the "Save" menu button is inactive and grayed out.
Welding procedures newly created via "Adjust Program" are saved in
the "Internal Memory" in the "STANDARD" folder.
Alternatively, welding procedures can also be saved selectively.
For detailed information, see the chapter
11
"Print Prev. Log”
softkey
The "Print Prev. Log" softkey can be used to print out the weld daa
log of the last weld, regardless of the weld data log settings in the
welding procedure.
This function must be activated in the "System Settings".
Содержание MOBILE WELDER OC PLUS
Страница 8: ...ENGLISH MOBILE WELDER OC PLUS 8 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Страница 20: ...ENGLISH MOBILE WELDER OC PLUS 20 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Страница 177: ...MOBILE WELDER OC PLUS ENGLISH ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com 177 ...
Страница 200: ...SPARE PARTS MOBILE WELDER OC PLUS 200 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Страница 204: ......