User interface, machine control panel
Version 1.1.2 dated 2019-05-07
Page 262
Translation of the original instructions
F80 | F105
GB
F
80_F105
_GB
_5.
fm
OPTIMUM
M A S C H I N E N - G E R M A N Y
®
5.4
Protection levels
SINUMERIK 808D provides a concept of protection levels for enabling data areas. Different
protection levels control different access rights.
The control system delivered from SIEMENS is set by default to the lowest protection level 7
(without password).
If the password is no longer known, the control system must be reinitialized with default
machine data. All passwords are then reset to default passwords for this software release.
ATTENTION!
Before you boot the control system with default machine data, make sure that you have
backed up your data; otherwise, all data is lost after rebooting with the default machine
data.
Program state keys
Cycle stop key
Stops the execution of NC programs
Cycle start key
Starts the execution of NC programs
Reset key
Resets NC programs
Cancels alarms that meet the cancel criterion.
Feedrate override switch
Traverses the selected axis at the specified feedrate override.
Excerpt from the manual of the operating instructions for "SINUMERIK 808D OPM Operation"
Element
Description
9
10
Protection level
Locked by
Area
0
Siemens password
Siemens, reserved
1
Manufacturer password
Machine manufacturers
2
Reserved
3 - 6
End-user password
(Default password: "CUSTOMER")
End users
7
No password
End users