Operating and Programming — Milling
Additional Information Part 1
Brief instruction 808D Milling
SEQUENCE
1
2
In the "local configuration data"
in the relevant parameters.
①
DHCP is set to "No"
②
IP address and subnet mask
can be arbitrarily set according
to need. (Right given only as
an example)
“Local Configuration Data"
setting finished, press the
"Save" button to activate the
data set.
When the "data storage end" is
displayed, the input data
activation effect.
Step 2
Set the PC's static IP address.
Ensure PC/PG is connected using a network
cable to rear X130 PPU Ethernet port.
Open the PC's network connection settings, in
the "local area connection properties" select
"Internet Protocol (TCP / IP)"
And double click “Properties”.
In the dialog box, select "Use the following IP
address" and fill in the required IP address.
(Shown right only given as an example)
Select "OK" to complete the setup.
Note: The address "10.10.10.2" setting is based
on the first step in the IP address of the PPU.
PPU and PC IP address should be kept in the
same network segment.