MDI-4000 Series Serial Interface Manual
41
5.3
Low Power
Low power mode helps to further reduce power consumption when the scan engine is in
standby mode. When the scan engine shifts from standby mode to low power mode, all scan
engine settings are retained.
5.3.1
Enable/Disable Low Power Mode
When you enable low power mode, you can configure the transition time. Transition time is the
amount of time the scan engine remains in standby mode before it changes to low power mode.
The default setting for transition time is 5 seconds.
Low Power Mode Enable/Disable Commands
Command
Description
Default
[XSC
Disable low power mode
✓
[EB8
Enable low power mode
5.3.2
Transition Time
The transition time (t
1
) indicates that the scan engine is in
“standby mode.” After the transition
time, the scan enters low power mode, and the POWERDWN signal becomes high.
Figure 23: Transition Time
Low Power Transition Time Commands
Item
Command
Description
Default
Low power
transition time
[EBA Qa Qb Qc Qd Set low power transition time with
numerical values
5 s
(1000a+100b+10c+d [s])
(0 - 9999)
* When this command is set to 0, the transition time is set to 150 ms.
Example Setting:
To e
nable “low power mode” and set the transition time so that the scan engine changes to low
power mode from standby mode after 3 seconds, use this command:
<Esc>[EB8[EBAQ0Q0Q0Q3<CR>
Note:
You should set this command when you set the Factory Default Settings. For more
information, see
“How to Permanently Change the Factory Default Settings” on page 11
POWERDWN
GR_LEDn
TxD
USB
Data
t
1
t
D
Содержание MDI-4000 Series
Страница 4: ...MDI 4000 Series Serial Interface Manual iv...
Страница 12: ...MDI 4000 Series Serial Interface Manual xii...