38
Power Mode Descriptions
Status
Description
Read
The scan engine is reading a barcode. Both the white LED and the green
aiming light are on.
Standby
The scan engine is ready to read a barcode.
Low Power
The scan engine is in a low power consumption state. You can configure the
amount of time the scan engine remains in standby mode before it changes to
low power mode. For more information, see
“Low Power” on page 41
AIM
When the AIM signal is ON, the green aiming light is on.
5.2
Current Consumption
Before integrating the scan engine, make sure you are familiar with the current consumption
specifications.
5.2.1
Absolute Maximum Ratings
Note:
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent
damage to the device. These are stress ratings only, and functional operation of the device at
these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute maximum rated conditions for extended periods
of time may affect device reliability.
Item
Symbol
Rated Value
Unit
Power Supply Voltage
V
CC
-0.3 to 7.0
V
Input Voltage
V
I
-0.3 to V
CC
+0.3
V
5.2.2
Recommended Operating Conditions
Item
Symbol
Conditions Min.
Typ.
Max.
Unit
Supply Voltage
V
CC
3.0
3.3/5.0
5.5
V
Input
Voltage
Low
V
IL
0
-
0.15
V
High
V
IH
V
CC
-0.4
-
V
CC
V
Output
Voltage
Low
V
OL
I
OL
= 600µA
-
0.55
V
High
V
OH
I
OH
= -20µA
0.67* V
CC
-
V
CC
V
Output
current
Low
I
OL
V
CC
= 3.0V
-4
mA
High
I
OH
V
CC
= 3.0V
4
mA
5.2.3
Peak Current Consumption
(V
CC
= 3.3V/5.0V T
A
= 25°C)
Item
State
Symbol Conditions Min.
Typ.
Max.
Unit
Peak Rush Current *
Boot
I
PK
-
-
800
1000
mA
*