MDI-4000 Series Serial Interface Manual
39
5.2.4
Current Consumption of the MDI-4x00
UART
[ V
CC
= 3.3V]
(IF:UART, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol Conditions Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
300
450
mA
Standby
Current
Standby
0 ms
I
STB
-
-
26
mA
Low
Power
18 ms
I
LOW
Configured
-
9
mA
[ V
CC
= 5.0V]
(IF:UART, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol Conditions Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
210
320
mA
Standby
Current
Standby
0 ms
I
STB
-
-
23
mA
Low
Power
18 ms
I
LOW
Configured
-
10
mA
*1
Recovery time is time until ready to scan.
USB
[ V
CC
= 3.3V]
(IF:UART, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol Conditions Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
300
450
mA
Standby
Current
Standby
0 ms
I
STB
-
-
46
mA
Low
Power
18 ms
I
LOW
Configured
-
28
mA
Low Power
Current
Suspend
18 ms
I
SUS
Configured
-
9
mA
[ V
CC
= 5.0V]
(IF:UART, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol Conditions Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
210
320
mA
Standby
Current
Standby
0 ms
I
STB
-
-
32
mA
Low
Power
18 ms
I
LOW
Configured
-
20
mA
Low Power
Current
Suspend
18 ms
I
SUS
Configured
-
10
mA
*1
Recovery time is time until ready to scan.
Содержание MDI-4000 Series
Страница 4: ...MDI 4000 Series Serial Interface Manual iv...
Страница 12: ...MDI 4000 Series Serial Interface Manual xii...