
MDI-4000 Series Serial Interface Manual
9
3.2
Precautions for Sending Command Packets
*1
Only configures the factory default settings in an environment where power is stable.
*2
These areas are cleared when a firmware update is loaded. They can be rewritten up to 100,000 times.
Figure 6: Precautions for Sending Command Packets
Active Settings
in RAM
Startup Settings
Stored in flash
*1*2
Custom Settings
Stored in flash
Factory Defaults
Stored in flash
Power on/Reset
Copy the startup settings
to active settings
Z2 command
Copy the active settings
to startup settings
[BAP command
Copy the custom settings
to active settings
[BAQ command
Copy the active settings
to custom settings
Serial command
Changes one or
more active settings
Default command or
firmware update
Copy the factory defaults
to active settings
[EFY command
Changes one or
more settings
*2
*1
*1
Содержание MDI-4000 Series
Страница 4: ...MDI 4000 Series Serial Interface Manual iv...
Страница 12: ...MDI 4000 Series Serial Interface Manual xii...