MDI-4000 Series Serial Interface Manual
11
3.2.3
Custom Settings
To save Active Settings to Custom Settings, send the [BAQ command at the end of command
packet you want to save. To save Custom Settings and Active Settings at same time, send the
[BAQZ2 command.
Custom Settings Commands
Command
Description
[BAP
Read out Custom Settings
[BAQ
Save to Custom Settings
* Saving Custom Settings over 100,000 times may destroy memory. If you need to configure these settings
frequently, avoid saving every time.
3.3
How to Permanently Change the Factory Default Settings
You can use the Custom Command Line commands to permanently change the Factory Default
Settings. The new Factory Default Settings become active after the scan engine is rebooted and
initialized and persist through a firmware update.
Note:
Custom Command Line commands may corrupt flash memory if power is turned off while
they are being configured. Only use these commands in an environment where the power is
stable.
Recommended Custom Command Line Settings:
•
Fast Boot Mode (See
“Fast Boot Mode” on page 12
.)
•
Image settings (See
“Mirrored Image” on page 15
.)
•
Serial communication commands like baud rate, data length, parity, and stop bit. (
See
.)
Custom Command Line Commands
Command
Header
Command
Separator
Command IDs*
Separator
Command
Terminator
<ESC>
[EFY
’
(0x27)
Custom Commands
’
(0x27)
<CR>
*
Multiple commands are allowed.
To activate the new Factory Default Settings, send or scan the RV command to reset the scan
engine.
To load the new Factory Default Settings, send or scan the U2 command to save the new
settings and load them after the scan engine is powered up.