MDI-4000 Series Serial Interface Manual
95
8.3.2
Auto Trigger Sensitivity
You can configure the sensitivity of the scan engine to detect barcodes. Sensitivity is affected by
environmental conditions, so you need to adjust this setting accordingly.
Auto Trigger Sensitivity Commands
Command
Description
Default
[XMF
High sensitivity
[XMH
Normal sensitivity
✓
[XMJ
Low sensitivity
8.3.3
Double Read Reset Time
When auto trigger mode is enabled, you can set the time interval in which the same barcode
can be read again. When a barcode with different data is read, this command is reset.
Double Read Reset Time Commands
Command
Description
Default
(valid range)
[D3R
Qa
Qb
Qc
Qd
Double read reset time
(1000a+100b+10c+d) [ms]
700 ms
(0 - 9999)
*
When this command is set to 0 seconds, the same barcode will not be read.
8.3.4
Read Time Adjustment
Lets you configure when to end auto trigger scanning.
Auto Trigger Read Time Adjustment Commands
Command
Description
Default
[EFH
Long time
[EFI
Normal time
✓
[EFJ
Short time
*
When the read time is
set to “Y0,” the read time is automatically set by image processing. For more information,
see
“Read Time” on page 49
8.3.5
Auto Trigger Sleep Mode
If the scan engine does not detect a barcode after a specified period of time, the scan engine
transitions to sleep mode. At specified time intervals, the scan engine tries to detect a barcode.
If a barcode is detected or if the trigger is pulled, the scan engine exits sleep mode. To disable
sleep mode transition, set this command to 0 seconds.
Auto Trigger Sleep Mode Commands
Command
Description
Default
(valid range)
[EBW
Qa
Qb
Qc
Qd
Transition time to sleep mode
(1000a+100b+10c+d) [s]
5 s
(0 - 9999)