Opticon MDI-4000 Series Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

Serial Interface Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MDI-4000 Series 

MDI-4000, MDI-4050, MDI-4100, MDI-4150 

Low Profile, High-Performance, 2D Imager Engine 

 

Содержание MDI-4000 Series

Страница 1: ...Serial Interface Manual MDI 4000 Series MDI 4000 MDI 4050 MDI 4100 MDI 4150 Low Profile High Performance 2D Imager Engine...

Страница 2: ...roducts that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard re...

Страница 3: ...evision History Product Name MDI 4000 Series Serial Interface Manual Edition Date Page Section Description of Changes 2nd February 28 2020 Applied new template Rewrote text for clarity 1st June 11 201...

Страница 4: ...MDI 4000 Series Serial Interface Manual iv...

Страница 5: ...Command Packets 9 3 2 1 Factory Default Settings 10 3 2 2 Save Settings 10 3 2 3 Custom Settings 11 3 3 How to Permanently Change the Factory Default Settings 11 3 4 Fast Boot Mode 12 3 5 Basic Comma...

Страница 6: ...ation 29 4 2 4 Integration USB Driver 29 4 2 5 Connection Confirmation USB COM 29 4 2 6 Fixed USB COM Port 30 4 2 7 Connection Method 30 4 2 8 COM to HID Output WIME 30 4 2 9 Troubleshooting USB COM 3...

Страница 7: ...wer Mode Communication Sequence 42 5 4 How to Recover from Low Power Mode 43 5 4 1 Recover from Low Power Mode by Signal UART 43 5 4 2 Recover from Low Power Mode by Command UART 45 5 4 3 Recover from...

Страница 8: ...e 39 and Italian Pharmaceutical 67 6 3 4 Codabar 69 6 3 5 Interleaved 2 of 5 and S Code 70 6 3 6 Code 128 71 6 3 7 IATA 72 6 3 8 MSI Plessey 73 6 3 9 UK Plessey 73 6 3 10 Telepen 73 6 3 11 Code 11 73...

Страница 9: ...3 Double Read Reset Time 94 8 3 4 Read Time Adjustment 94 8 3 5 Auto Trigger Sleep Mode 94 8 3 6 Detection Mode 95 8 4 Illumination and Aiming 95 8 4 1 Reading LED Illumination 95 8 4 2 External LED...

Страница 10: ...Value 102 10 2 MDI 4xx0 Specification Overview 107 10 2 1 Common Specification Overview 107 10 2 2 Technical Specifications 108 10 2 3 MDI 4xx0 Detailed View 112 10 3 Sample Barcodes 116 10 3 1 1D Bar...

Страница 11: ...ion Time 41 Figure 24 USB Low Power Mode Communication Sequence 43 Figure 25 Recovery Example Using TRIGn Signal 44 Figure 26 Recovery Example Using Commands 45 Figure 27 Recovery Example from Low Pow...

Страница 12: ...MDI 4000 Series Serial Interface Manual xii...

Страница 13: ...or The high speed CMOS image sensor captures images at a speed of up to 100 fps which when combined with the fastest global shutter speed in the industry enables fast and accurate scanning Ultra fast...

Страница 14: ...acquisition and communication USB Driver For USB COM WIME For COM output to HID output conversion 3 Configure and Test the Scan Engine Evaluate the scan engine settings in your scanning environment a...

Страница 15: ...D UD B DC D MDI 4000 SR HD UD B DC D Focus Description Focus Description SR Standard Range 115 mm HD High Density 65 mm UD Ultra High Density 45 mm Interface Description Interface Description B UART D...

Страница 16: ...wer consumption mode installed MDI 4050 Decoder board mounted to camera Low power consumption mode installed MDI 4100 Decoder board separate from camera MDI 4000 Decoder board mounted to camera 2 2 Sc...

Страница 17: ...ation Board Accessory The MEK 3100 evaluation board can perform these tasks Confirm the connection Connects the scan engine to the host through an RS 232C or USB interface and monitors each signal in...

Страница 18: ...engine by sending commands through the serial interface or by reading 1D or 2D menu labels This section describes the serial commands 3 1 1 Command Packet This table defines the command packet from he...

Страница 19: ...ESC is automatically sent Figure 5 Opticon s Universal Config 3 1 2 Sending Command Packets The maximum length of a command packet is 1000 characters If more than 1000 characters are sent the scan en...

Страница 20: ...er to this signal for the correct timing For more information see Handshaking Flow Control on page 22 Use ACK NAK for serial commands When this command is enabled the scan engine sends an ACK after a...

Страница 21: ...ve Settings in RAM Startup Settings Stored in flash 1 2 Custom Settings Stored in flash Factory Defaults Stored in flash Power on Reset Copy the startup settings to active settings Z2 command Copy the...

Страница 22: ...tings for the scan engine When the default command U2 is read or sent these settings are loaded to Active Settings You can modify Factory Default Settings through Custom Command Line Settings For more...

Страница 23: ...he scan engine is rebooted and initialized and persist through a firmware update Note Custom Command Line commands may corrupt flash memory if power is turned off while they are being configured Only...

Страница 24: ...FZ Output configured commands in custom command line Example output EFXQ1WC D1Z EFU E8ISZ EB8 EBAQ0Q0Q0Q2 Note If no Custom Command Line commands have been configured the scan engine will not send any...

Страница 25: ...e read time with the Z command is set to Indefinitely and reading continues until a Y command is received For timeout limited reading use the Yx commands For more information see Read Timing on page 4...

Страница 26: ...S Mode I F mode SU USB HID Keyboard I F mode C01 USB Virtual COM I F mode Q3 Focus type SR SR Standard Range 115 mm fixed focus HD High Density 65 mm fixed focus UD Ultra High Density 45 mm fixed foc...

Страница 27: ...Q0 Q1 Enable 1D menu barcode when using TRIGn signal Q0 Q0 Disable 1D menu barcode when using TRIGn signal Q2 Q1 Enable 1D menu barcode when using software trigger Q2 Q0 Disable 1D menu barcode when...

Страница 28: ...Vertical Mirrored Image EFU E8I Disable Enable 180 Rotated Image EFV E8I Enable Enable Figure 9 Mirrored Image Configurations Horizontal Mirror Horizontal Mirror Vertical Mirror Vertical Mirror Norma...

Страница 29: ...mmand requires additional numerical input Include these commands in a single packet with the command that requires the numerical input Direct Input Numerical Values Command Description Notes Q0 0 Inpu...

Страница 30: ...tiple settings that are processed in order in a single operation So you can configure multiple settings for the scan engine by reading a single 2D menu barcode Scanning a 2D menu barcode automatically...

Страница 31: ...ent to the host device Force the Scan Engine to Initialize 1 Turn off the scan engine 2 While keeping TRIGn Low turn on the power 3 With TRIGn low wait for at least 10 seconds TRIGn becomes active and...

Страница 32: ...rol signal in other states than Low Power In L Aiming LED on H Aiming LED off 3 GR_LEDn Good read LED Out L LED on H LED off 4 7k pull up on module EX_ILLUM Control of an external light source Out Con...

Страница 33: ...baud rate To activate and save the new configuration you need to use the Z2 command save settings in non volatile memory Note You should configure these settings at Custom Factory Default Baud Rate Co...

Страница 34: ...ven parity L4 Odd parity Stop bit L5 1 stop bit L6 2 stop bits 4 1 6 Handshaking Flow Control Handshaking is a communication control method To activate and save the new configuration you need to use t...

Страница 35: ...that the host is ready to receive data by seeing if its CTS line is on If the CTS line is off the scan engine does not send the data and waits for a specific timeout period for the CTS line to be turn...

Страница 36: ...e scan engine s CTS line OFF While the RTS line is ON if the CTS line is not ON for a certain configurable period the scan engine ends the transmission and uses the buzzer to indicate an error Figure...

Страница 37: ...y XI5 100 ms XI6 500 ms XI7 1 s Start of transmission Transmit data Start 1 sec timer As configured Response received Timer ended Response NAK Response ACK Response DC1 ERROR Buzzer ERROR Buzzer GOOD...

Страница 38: ...within 100 ms the scan engine terminates transmission with the good read buzzer Figure 20 ACK NAK No Response Flowchart 4 1 7 Inter Character Delay UART Inter character delay adds a configurable dela...

Страница 39: ...t the code to be read matches to the character code of the communication tool Nonsensical characters Make sure the communication settings are correct Check the line break setting of the communication...

Страница 40: ...trol of an external light source Out Configured 1 L External Illumination On H External Illumination Off 4 BUZZERn Buzzer Out 100k pull up on module 2 5 POWERDWN Indicates Low Power state Out L Normal...

Страница 41: ...soft Windows the driver is automatically downloaded when the host connects to the Internet If you are running Linux the driver should already be installed Download the USB Driver 1 Go to the Downloads...

Страница 42: ...ault EGC Q0 Do not assign a fixed COM port number Q1 Assign a fixed COM port number 4 2 7 Connection Method After you install the driver and configure the fixed USB COM port setting you can connect th...

Страница 43: ...ct the scan engine to a different port Scan engine does not appear in the device manager Try the possible solutions for the previous problem Open the COM port with the communication tool Error beep so...

Страница 44: ...er states than Low Power In L Aiming LED on H Aiming LED off 3 GR_LEDn Good read LED Out L LED on H LED off 100k pull up on module EX_ILLUM Control of an external light source Out Configured 1 L Exter...

Страница 45: ...lue No interval Suspend mode Remote wakeup Use when host system is using suspend Initial value Valid Keyboard language Set according to the keyboard language Initial value English USA Character code S...

Страница 46: ...ting data toggle the CapsLock status again 3 CapsLock status is configured to display the original string Use this command to return to the original CapsLock status when data transmission is complete...

Страница 47: ...used on the host PC Note Character arrangement on the keyboard depends on the country or language If the setting is incorrect the output results will also be incorrect Keyboard Language Commands Comm...

Страница 48: ...application with USB COM For more information see COM to HID Output WIME on page 30 Line break is doubled Configure the additional suffix setting based on the host application s line break Cannot outp...

Страница 49: ...Low Power Mode Power ON OFF Timing Read Timing 5 1 Power Mode Transition 1 These options are available to reduce start up time Fast Boot and Normal Boot 2 When Low Power Standby is enabled the scan e...

Страница 50: ...s may cause permanent damage to the device These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Cond...

Страница 51: ...23 mA Low Power 18 ms ILOW Configured 10 mA 1 Recovery time is time until ready to scan USB VCC 3 3V IF UART TA 25 C Item State Recovery Time 1 Symbol Conditions Min Typ Max Unit Operating Current Re...

Страница 52: ...ured 0 9 mA 1 Recovery time is time until ready to scan USB VCC 3 3V IF USB TA 25 C Item State Recovery Time 1 Symbol Conditions Min Typ Max Unit Operating Current Read IOP 300 450 mA Standby Current...

Страница 53: ...sition Time The transition time t1 indicates that the scan engine is in standby mode After the transition time the scan enters low power mode and the POWERDWN signal becomes high Figure 23 Transition...

Страница 54: ...the hub This feature helps conserve battery power You can set selective suspend for USB COM using the USB as a virtual COM and USB HID using the USB for key code input communications Set Selective Sus...

Страница 55: ...4 1 Recover from Low Power Mode by Signal UART You can use a signal TRIGn CTS and AIM WAKEn to recover from low power mode If you need to send additional commands they will be accepted when the RTS or...

Страница 56: ...S signal is High 2 MDI 4x00 and MDI 4x50 have different recovery times MDI 4x00 18 ms MDI 4x50 41 ms Figure 25 Recovery Example Using TRIGn Signal Read Standby Low Power IOP 10 ms TRIGn ILOW Configure...

Страница 57: ...To start reading send the trigger command Z 4 If you need to send additional commands confirm that the RTS or POWERDOWN signal is low 1 Cannot be used when Handshaking is set to MODEM because the RTS...

Страница 58: ...e command is sent the scan engine becomes active and is ready to read barcodes Note USB always accepts the command and changes to Active mode when it sends the command 1 MDI 4x00 and MDI 4x50 have dif...

Страница 59: ...Max Unit Normal Boot 510 ms Fast Boot Mode Configured 425 ms For more information see Fast Boot Mode on page 12 5 5 2 Power Off Timing When the power is turned off while an input signal to the scan en...

Страница 60: ...ed Writing these settings to flash memory can take up to 10 seconds Make sure the power is not turned off during this period or the settings may be corrupted Note When the Z2 command is sent if ACK NA...

Страница 61: ...g Commands Command Description Notes Y0 Trigger signal synchronization or Z Y command control Y1 1 second Y2 2 seconds Y3 3 seconds Y4 4 seconds Y5 5 seconds Y6 6 seconds Y7 7 seconds Y8 8 seconds Y9...

Страница 62: ...mand Figure 34 Command Trigger Control The scan engine stops reading a barcode when the read time elapses You can also stop the scan engine from reading a barcode by sending the Y command Figure 35 Co...

Страница 63: ...fect reading 1D menu barcodes Note For best reading performance only enable the barcodes you need 6 1 How to Set Readable Barcodes The next tables show the supported symbologies and their configuratio...

Страница 64: ...K 5 Code 128 A6 B6 VE 1 Code 93 A5 B5 VD 1 IATA A4 B4 VH 5 MSI Plessey A7 B7 VF 3 UK Plessey A1 B1 VA 2 Telepen A9 B9 VG 1 Code 11 BLB BLC BLA 1 Matrix 2 of 5 AB BB DDL 5 For more information about ho...

Страница 65: ...SL For more information about how to convert GS1 see GS1 Conversion on page 55 6 1 3 GS1 Composite Code Symbologies Enable Disable Command Default Multiple Disable Enable Suffix Composite GS1 DataBar...

Страница 66: ...l 2D barcodes BCB BCN BCZ 1 2 1 PDF417 Codablock F QR Code Data Matrix ECC 200 Maxi Code Micro PDF417 Aztec Code Composite code Aztec Runes Micro QR and Chinese sensible code 2 When ALL 2D barcodes is...

Страница 67: ...ptions to convert the GS character to a printable character By default GS characters are not transmitted but you can enable sending these characters with or without conversion Additionally the GS1 org...

Страница 68: ...ed The previous example would produce this output 01950123456789033103000123 Enable GS1 conversion 2 Braces are put around the AI identifiers similar to human readable text under a barcode The previou...

Страница 69: ...d negative barcodes For best reading performance only enable the barcodes you need 6 2 3 Quiet Zone 1D Code Common The quiet zone is the blank margin on either side of a barcode that tells the scan en...

Страница 70: ...undancy 5 BU Read 7 times redundancy 6 BV Read 8 times redundancy 7 BW Read 9 times redundancy 8 6 2 5 Add On Waiting Time When you scan one of these UPC EAN barcodes the scan engine searches for a va...

Страница 71: ...M ID from ECI protocol implemented to ECI protocol not implemented delete the 6 digit number and replace the two backslashes with one backslash Output example Output data for ECI protocol Q2 000001tes...

Страница 72: ...ming Manual To configure settings that cannot be set contact your local Opticon Representative 6 3 How to Set Code Specific Options 6 3 1 UPC UPC which technically refers to UPC A is a barcode develop...

Страница 73: ...er of digits 12 digits 11 digits plus a 1 digit CD fixed length CD method Modulus 10 Wait 3 UPC A Transfer Data Format Digit Description Leading 0 Yes Data 11 digits CD 1 digit To make the format comp...

Страница 74: ...he reading range for the barcode to be successfully read If the add on code is not within the reading range after an add on waiting time the scan engine reads the barcode as UPC or EAN Note Reading re...

Страница 75: ...ns Character set Numeric 0 9 Number of digits 7 digits 6 digits plus a 1 digit CD fixed length CD method Modulus 10 Wait 3 UPC E Transfer Data Format Digit Description Leading 0 Yes Data 6 digits CD 1...

Страница 76: ...s UPC E UPC E leading zero CD transmission E6 UPC E leading zero transmit CD 8 transfer digits E7 UPC E no leading zero transmit CD 7 transfer digits 7 E8 UPC E leading zero do not transmit CD 7 trans...

Страница 77: ...fully read If the add on code is not within the reading range after an add on waiting time the scan engine reads the barcode as UPC or EAN Note Reading response decreases when add on digits are enable...

Страница 78: ...e leading 4 digits to M and outputs 10 digits When ISMN conversion is disabled and ISBN conversion is enabled EAN 13 data with a leading 9790 is converted to ISBN format ISMN Conversion Example ISMN c...

Страница 79: ...ble EAN JAN 13 Add on 2 digits Add on 5 digits JI Enable single EAN JAN 13 Add on 5 digits JW Add enable EAN JAN 13 Add on 5 digits X4P Disable EAN JAN 13 Add on 5 digits EAN 13 EAN 13 Forced add on G...

Страница 80: ...able EAN JAN 8 Add on 5 digits 6 3 3 Code 39 and Italian Pharmaceutical Code 39 is a barcode developed by Intermec and has been standardized as ISO IEC 16388 Code 39 is mainly used in the Industrial f...

Страница 81: ...a followed by a mandatory 1 digit CD If the data is not correctly converted to Italian Pharmaceutical format the data is not sent Italian Pharmaceutical if possible Converts Code 39 data to Italian Ph...

Страница 82: ...Read Mode Mode Description Standard Consists of 1 barcode ABC ABC is an acronym for the American Blood Commission It consists of 2 side by side barcodes Margin is necessary When the barcode s first st...

Страница 83: ...tart stop code DC1 DC2 DC3 DC4 DC1 DC2 DC3 DC4 Space insertion HE Disable space insertion HD Enable space insertion ABC CX conversion HA Enable only Codabar normal mode H4 Enable only ABC code H5 Enab...

Страница 84: ...character gap or space which is the multiple width of a narrow bar between characters Use Industrial 2 of 5 Space Check to check for this space Interleaved 2 of 5 and Industrial 2 of 5 Optional Setti...

Страница 85: ...ll of the data in the buffer is sent You can concatenate a maximum of 400 characters The read time is updated each time the scan engine scans a barcode label If the barcode is not read within the read...

Страница 86: ...2 6 3 9 UK Plessey Setting Command Description Default CD transmission 4O Do not transmit CD 4N Transmit CD Space insertion DO Disable space insertion DN Enable space insertion X conversion DP Conver...

Страница 87: ...anded GS1 DataBar Expanded Stacked Symbologies not intended for retail point of sale GS1 DataBar Truncated GS1 DataBar Limited GS1 DataBar Stacked GS1 Databar bar codes encode a GTIN 12 or GTIN 13 in...

Страница 88: ...ed Transfer Data Format Digit Description AI 01 Data 13 digits CD 1 digit GS1 DataBar Expanded Transfer Data Format Digit Description Data 1 to 74 digits GS1 Conversion You can configure GS1 conversio...

Страница 89: ...r and UPC EAN Composite part CC A and CC B are same as Micro PDF417 CC C is same as PDF417 Error correction 1D part error detection only Composite par Reed Solomon error correction Link flags GS1 Data...

Страница 90: ...0 characters Byte compression 1108 characters Numeric compression 2710 characters Maximum digits Micro PDF417 Text compression 250 characters Byte compression 150 characters Numeric compression 366 ch...

Страница 91: ...set of 8 bit code for Katakana character 4 Chinese character Character specified by the shift coded expression of JIS X 0208 Maximum digits Alphanumeric data 4296 characters 8 bit data 2953 character...

Страница 92: ...Version M2 13 x 13 module Read Solomon error correction 2 steps L M Version M3 15 x 15 module Read Solomon error correction 2 steps L M Version M4 17 x 17 module Read Solomon error correction 3 steps...

Страница 93: ...ns square or rectangle Square minimum 10 x 10 maximum 144 x 144 module Rectangle minimum 8 x 18 maximum 16 x 48 module 6 patterns Error correction ECC200 Set automatically Negative barcode mirror prin...

Страница 94: ...ECI Protocol Output on page 59 Maximum number of digits Alphanumeric data 3067 characters Numeric data 3832 characters Byte 1914 characters Symbol size Minimum 15 x 15 module Maximum 151 x 151 module...

Страница 95: ...imum length checking for each barcode type and only affects the specified barcode types Fixed Length Configuration Commands Command Description Default valid range Specify Code Input length of digits...

Страница 96: ...r DCF DBF DAF Composite DCG DBG DAG GS1 128 DCC DBC DAC S code DC5 DB5 DA5 UK Plessey DCA DBA DAA Matrix 2 of 5 Chinese Post DC6 DB6 DA6 Telepen DC9 DB9 DA9 Codablock F DCO DBO DAO Code 11 DCE DBE DAE...

Страница 97: ...e Optical Character Recognition on page 59 and OCR Barcodes on page 54 Preamble Postamble You can add a preamble or postamble of up to 8 digits to the data string For all barcode symbologies you can s...

Страница 98: ...efix suffix RY RZ Common prefix Common suffix MZ PS By default CR is added to the prefix or suffix for all barcodes To clear CR send the RZ command only Barcode Prefix and Suffix Commands Barcode Pref...

Страница 99: ...Z Machine Readable Passports DJJ DJP Machine Readable Visas A DJK DJQ Machine Readable Visas B DJL DJR Official Travel Documents 1 DJM DJS Official Travel Documents 2 DJN DJT ISBN DJO DJU 7 2 3 Prefix...

Страница 100: ...1G 5I I 0I i I H BS 1H 5J J 0J j J I HT 1I 5K K 0K k K J LF 1J 5L L 0L l L K VT 1K 5M M 0M m M L FF 1L 5N N 0N n N M CR 1M 5O O 0O o O N SO 1N 5P P 0P p P O SI 1O 6A Q 0Q q Q P DLE 1P 6B R 0R r R Q D...

Страница 101: ...e ID to the all codes prefix send this command Esc RY 2 CR 7 2 3 3 Code Length To add the code length send a code length command with the command to set a prefix suffix For 1D barcodes the code length...

Страница 102: ...put format X Y where X 1 to 3 digits Y 1 to 3 digits The range of the coordinates is X 0 to 639 Y 0 to 479 Figure 41 Code Coordinates 7 2 3 5 Scan Time The scan time is the time from when the trigger...

Страница 103: ...ode Command Description Default Single Read S0 Single read in a single trigger press Multiple Read 1 D3P Multiple reads in a single trigger press the scan engine saves the data in memory and does not...

Страница 104: ...ss and keeps reading even after a barcode is successfully decoded until the read time expires In Multiple Read Mode 2 the scan engine reads the same barcode in a single trigger press if one of these c...

Страница 105: ...Trigger Repeat function Trigger Repeat helps properly aim the scan engine before scanning a barcode This function helps improve reading performance when reading barcodes that are tightly packed togeth...

Страница 106: ...cts and reads barcodes 8 3 1 Auto Trigger Modes You can configure these two auto trigger modes Presentation auto trigger mode Use this mode when the scan engine is in a fixed position and barcodes are...

Страница 107: ...When this command is set to 0 seconds the same barcode will not be read 8 3 4 Read Time Adjustment Lets you configure when to end auto trigger scanning Auto Trigger Read Time Adjustment Commands Comma...

Страница 108: ...ation detection DDI No illumination detection 8 4 Illumination and Aiming You can enable or disable warm white illumination and green LED aiming 8 4 1 Reading LED Illumination You can enable or disabl...

Страница 109: ...signal Disables Good Read Output Signal 8 4 3 LED Aiming You can enable or disable the green aiming LED as well as configure the brightness LED Aiming Commands Command Description Default D3D Enable L...

Страница 110: ...re options for the Buzzer and Good Read LED 9 1 Buzzer The scan engine provides feedback through these buzzer indicators Good read Startup Read timeout Intermediate The BUZZERn signal controls the buz...

Страница 111: ...Description Default W1 Medium frequency buzzer 3000 Hz 3000 Hz W2 2 step buzzer tone high to low W3 2 step buzzer tone low to high Good Read Buzzer Tone Frequency Commands Command Description Default...

Страница 112: ...he idle level of the BUZZERn pin to minimize power consumption when the buzzer is not active For example when a PNP transistor is used to drive the buzzer the transistor is open when the BUZZERn signa...

Страница 113: ...onfigure the frequency and duration of this light Good Read Aiming Commands Command Function Description Default EF3 Qa Qb Qc a Settings 0 Indicator frequency 1 First indicator duration after reading...

Страница 114: ...aBar y UPC E 2 H CC A m UPC E 5 I CC B n EAN 13 B CC C l EAN 13 2 L Korean Postal Authority c EAN 13 5 M Intelligent mail 0 EAN 8 A Postal TNT KIX 1 EAN 8 2 J Japanese postal code 2 EAN 8 5 K Postnet...

Страница 115: ...E7 GS1 DataBar e0 EAN 8 5 E7 CC A e1 Code 39 A CC B e1 Code 39 Full ASCII A CC C e1 Tri Optic X0 GS1 DataBar with CC A e0 Code 39 lt Pharmaceutical X0 GS1 DataBar with CC B e0 Codabar F GS1 DataBar w...

Страница 116: ...CII Code 39 if pos K Check CD C0 Do not transmit CD D8 A7 Codabar Option AIM ISO15424 Code ID F Code Option AIM ID Code Option AIM ID Codabar normal mode HA Do not check CD H7 Transmit CD H8 F0 Codaba...

Страница 117: ...10 4B Check 2CD s MOD 10 MOD 11 4D 4D Transmit CD1 4E or 4D Do not transmit CD 4G or 4D Transmit CD1 and CD2 4F X0 4B Transmit CD1 4E or M0 4B Do not transmit CD 4G or M1 4B Transmit CD1 and CD2 4F X0...

Страница 118: ...LI length 12 Transmit CD S BLK H1 Do not check CD BLF Do not transmit CD BLJ H3 Codablock F Option AIM ISO15424 Code ID O Code Option AIM ID Code Option AIM ID FNC1 not used O4 FNC1 in 1st position O5...

Страница 119: ...implemented zA FNC1 following an initial letter or pair of digits ECI protocol implemented z5 Structured append header included z6 Structured append header included FNC1 following an initial letter o...

Страница 120: ...ace Section Specifications Specification Value Notes UART 300 bps to 115200 bps Default 9600bps USB Full Speed 12Mbps HID COM Optical Section Specifications Specification Value Notes Scanning method M...

Страница 121: ...ty Fluorescent 10 000 lx or less UPC 0 33 mm Sunlight 100 000 lx or less 10 2 2 Technical Specifications Standard Model SR Reading Specifications Specification Value Minimum Resolution Code 39 0 1 mm...

Страница 122: ...m 2 9 99 mm 3 9 62 mm 2 4 113 mm 4 4 0 381 mm 15 mil QR Code 0 9 0 8 29 mm 1 2 216 mm 8 5 24 mm 1 0 252 mm 9 9 0 169 mm 6 7 mil Data Matrix 0 9 0 8 77 mm 3 0 103 mm 4 0 64 mm 2 5 118 mm 4 6 0 254 mm 1...

Страница 123: ...2 1 137 mm 5 4 48 mm 1 9 156 mm 6 1 0 127 mm 5 0 mil QR Code 0 9 0 8 51 mm 2 0 81 mm 3 2 45 mm 1 8 93 mm 3 7 0 381 mm 15 mil QR Code 0 9 0 8 33 mm 1 3 155 mm 6 1 26 mm 1 0 182 mm 7 2 0 127 mm 5 0 mil...

Страница 124: ...UPC EAN 0 9 0 8 68 mm 2 7 104 mm 4 1 52 mm 2 1 122 mm 4 8 0 084 mm 3 3 mil QR Code 0 9 0 8 44 mm 1 7 47 mm 1 9 35 mm 1 4 57 mm 2 2 0 381 mm 15 mil QR Code 0 9 0 8 31 mm 1 2 94 mm 3 7 24 mm 0 9 111 mm...

Страница 125: ...7 mm Weight Approx 5 5 g Height of the MDI 4100 and the MDI 4150 Figure 45 MDI 4100 and MDI 4150 Mechanical Drawing Product Label 21 6 0 1 21 0 5 3 9 0 3 2 5 0 1 4 5 2 4 Illumination LED Lens Aiming...

Страница 126: ...Serial Interface Manual 114 MDI 4100 and MDI 4150 Circuit Board The MDI 4100 and MDI 4150 have different circuit board thicknesses MDI 4100 MDI 4150 Figure 46 MDI 4100 and MDI 4150 Circuit Board 3 9...

Страница 127: ...ox 20 8 mm D 25 1 mm W 3 2 mm H Weight Approx 5 5g Figure 47 MDI 4000 and MDI 4050 Mechanical Drawing 1000001 MSI4000 UF1xx Illumination LED Lens Aiming LED lens Camera Lens Machine Screw M2x0 4 Depth...

Страница 128: ...DBM 4050 Decoder Board DBM 4000 and DBM 4050 Circuit Board The DBM 4000 and DBM 4050 have different circuit board thicknesses DBM 4000 DBM 4050 Figure 49 DBM 4000 and DBM 4050 Circuit Board IRISO 12p...

Страница 129: ...l 117 FPC Cable Figure 50 FPC Cable 10 3 Sample Barcodes 10 3 1 1D Barcodes UPC UPC A UPC A 2 UPC A 5 UPC E Connected to MOLEX 5042811900 19pin Connected to JST 17FXVL RSM1 GAN TF HF 17pin Shield area...

Страница 130: ...MDI 4000 Series Serial Interface Manual 118 UPC E 2 UPC E 5 EAN JAN EAN JAN 13 EAN JAN 13 2 EAN JAN 13 5 EAN JAN 8 EAN JAN 8 2 EAN 8 5 Code 39 Code 39 Code 39 Italian Pharmaceutical...

Страница 131: ...MDI 4000 Series Serial Interface Manual 119 Code 39 Full ASCII Tri Optic Codabar Codabar Codabar ABC Codabar CX Industrial 2 of 5 Interleaved 2 of 5 Industrial 2 of 5 Interleaved 2 of 5 S Code...

Страница 132: ...00 Series Serial Interface Manual 120 Code 128 Code 93 IATA MSI Plessey UK Plessey Telepen Code11 Matrix 2 of 5 10 3 2 Postal Code Chinese Post Matrix 2 of 5 Korean Postal Authority Intelligent Mail B...

Страница 133: ...MDI 4000 Series Serial Interface Manual 121 POSTNET PLANET Japan Postal Netherland KIX Code Australian Postal UK Postal Royal mail 4 State Mailmark Barcode...

Страница 134: ...ial Interface Manual 122 10 3 3 GS1 DataBar GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded GS1 DataB...

Страница 135: ...MDI 4000 Series Serial Interface Manual 123 10 3 4 GS1 Composite Code CC A CC B Limited CC A Limited CC B Expanded CC A Expanded CC B Composite GS1 128 CC A CC B CC C...

Страница 136: ...MDI 4000 Series Serial Interface Manual 124 Composite EAN EAN 13 CC A EAN 13 CC B EAN 8 CC A EAN 8 CC B Composite UPC UPC A CC A UPC A CC B UPC E CC A UPC E CC B...

Страница 137: ...MDI 4000 Series Serial Interface Manual 125 10 3 5 2D Barcodes PDF417 Micro PDF417 Codablock F QR Code Micro QR Data Matrix ECC 200 Aztec Code Aztec Runes Chinese sensible code Maxi Code...

Страница 138: ...8902C 3JPN4209247M16092711234567890 78 Machine readable Visa A V UTOERIKSSON ANNA MARIA L8988901C4XXX4009078F96121096ZE184226B Machine readable Visa B V UTOERIKSSON ANNA MARIA L8988901C4XXX4009078F961...

Страница 139: ...es Serial Interface Manual 127 OCR Font Free OCR Edit OCR A OCR B OCR A Free Edit Enable OCR A Free Edit Enable 4567890 0123456789012 DEFGHIJ 23456CDEFGH 345678 89012345678 FGHIJKLMN 56789012ABCD Free...