BASIC commands
PROGRAMMING MANUAL
70
Revi
si
on 3.0
3.2.84 DRIVE_INPUTS
/i
/i
3.2.85 DRIVE_MONITOR
/i
Type
Axis parameter
Syntax
DRIVE_INPUTS
Description
This parameter monitors the status of the inputs of the Servo Driver con-
nected via the MECHATROLINK-II bus. The parameter value is updated each
SERVO_PERIOD
cycle. It is a bit-wise word with the bits as listed in the table
below. The recommended setting is: Pn81E=4321 & Pn511=654x.
Arguments
N/A
Example
All inputs can be monitored in this word as follows (Sigma-II Servo Driver):
CN1-40 DRIVE_INPUTS bit 12
CN1-41 DRIVE_INPUTS bit 13
CN1-42 DRIVE_INPUTS bit 14
CN1-43 DRIVE_INPUTS bit 15
CN1-44 DRIVE_INPUTS bit 06
CN1-45 DRIVE_INPUTS bit 07
CN1-46 DRIVE_INPUTS bit 08
Example
All inputs can be monitored in this word as follows (Junma Servo Driver):
CN1-1 DRIVE_INPUTS bit 6
CN1-2 DRIVE_INPUTS bit 2
CN1-3 DRIVE_INPUTS bit 1
CN1-4 DRIVE_INPUTS bit 0
See also
N/A
Bit
number
Description Sigma-II
Description Junma
0
P_OT
P_OT
1
N_OT
N_OT
2
DEC Signal (selected with Pn511.0)
/DEC
3
Encoder Phase A
N/C
4
Encoder Phase B
N/C
5
Encoder Phase C
N/C
6
EXT1 Signal (selected with Pn511.1)
/EXT1
7
EXT2 Signal (selected with Pn511.2)
N/C
8
EXT3 Signal (selected with Pn511.3)
N/C
9
BRK Brake output
/BK
10
Reserved
E_STP
11
Reserved
N/C
12
IO12 (CN1 input signal selected in Pn81E.0) N/C
13
IO13 (CN1 input signal selected in Pn81E.1) N/C
14
IO14 (CN1 input signal selected in Pn81E.2) N/C
15
IO15 (CN1 input signal selected in Pn81E.3) N/C
Type
Axis parameter
Syntax
DRIVE_MONITOR
Description
This parameter contains the monitored data of the Servo Driver connected
to the system via the MECHATROLINK-II bus. The data to be monitored is
selected using
DRIVE_CONTROL
and can be displayed in the Trajexia
Tools scope or used inside a program. The monitored data is updated each
SERVO_PERIOD
.
Arguments
N/A
Example
No example.
See also
N/A
Bit
number
Description Sigma-II
Description Junma
I52E-EN-03.book Seite 70 Freitag, 29. Juni 2007 11:55 11