3.2.117 FE_LIMIT_MODE
/i
3.2.118 FE_RANGE
/i
3.2.119 FHOLD_IN
/i
Type
Axis parameter
Syntax
FE_LIMIT_MODE=value
Description
When this parameter is set to 0, the axis will cause a
MOTION_ERROR
immediately when the
FE
exceeds the
FE_LIMIT
value.
If
FE_LIMIT_MODE
is set to 1, the axis will only generate a
MOTION_ERROR
when the
FE
exceeds
FE_LIMIT
during 2 consecutive
servo periods. This means that if
FE_LIMIT
is exceeded for one servo period
only, it will be ignored.
The default value for
FE_LIMIT_MODE
is 0.
Arguments
N/A
Example
No example.
See also
N/A
Type
Axis parameter
Syntax
FE_RANGE
Description
The
FE_RANGE
axis parameter contains the limit for the Following Error
warning range in user units. When the Following Error exceeds this value on
a servo axis, bit 1 in the
AXISSTATUS
axis parameter will be turned on.
This range is used as a first indication for fault conditions in the application
(compare
FE_LIMIT
).
Arguments
N/A
Example
No example.
See also
AXIS
,
AXISSTATUS
,
ERRORMASK
,
FE
,
UNITS
.
Type
Axis parameter
Syntax
FHOLD_IN
FH_IN
Description
The
FHOLD_IN
axis parameter contains the input number to be used as the
feedhold input. The valid input range is 0 to 31. Values 0 to 15 represent phys-
ically present inputs of TJ1-MC__ I/O connector and are common for all axes.
Values 16 to 27 represent software inputs which can be freely used in pro-
grams and commands such as IN and OP. These are also common for all
axes. Values 28 to 31 are directly mapped to driver inputs present on CN1
connector, and they are unique for each axis. Which driver inputs are mapped
to inputs 28 to 31 depends on Servo Driver parameter Pn81E setting. Recom-
mended setting is Pn81E = 0x4321, with the following mapping: As default the
parameter is set to -1, no input is selected.
Note: This input is active low.
Sigma II
•
input 28: CN1-40
•
input 29: CN1-41
•
input 30: CN1-42
•
input 31: CN1-43
Sigma III
•
input 28: CN1-13
•
input 29: CN1-7
•
input 30: CN1-8
•
input 31: CN1-9
Junma
•
input 26: CN1-2
•
input 27: CN1-1
For more information on setting driver parameter Pn81E, see Servo Driver
manual. As default the parameter is set to -1, no inputs selected.