Trajexia Tools interface
PROGRAMMING MANUAL
217
Revi
si
on 3.0
an output is on, the input state does not change. The same
situation exists if an output goes into a current limit due to a
fault or overload.
•
Show description: Checking the Show Description check box
will toggle between descriptions on, and descriptions off.
Descriptions are stored in the project file.
Keypad
Not applicable for Trajexia.
Jog Axes
fig. 40
This window allows the user to move the axes on the Trajexia.
This window takes advantage of the bi-directional virtual I/O
channels (16 to 27) on the Trajexia to set the jog inputs. The
forward, reverse and fast jog inputs are identified by writing to the
corresponding axis parameters and are expected to be connected
to NC switches. This means that when the input is on (+24 V
applied) then the corresponding jog function is DISABLED and
when the input is off (0 V) then the jog function is ENABLED.
The jog functions implemented here disable the fast jog function,
which means that the speed at which the jog will be performed is
set by the JOGSPEED axis parameter. What is more this window
limits the jog speed to the range 0..demand speed, where the
demand speed is given by the SPEED axis parameter.
Before allowing a jog to be initiated, the jog window checks that all
the data set in the jog window and on the Trajexia is valid for a jog
to be performed.
Jog reverse
: This button will initiate a reverse jog. In order to do
this, the following check sequence is performed
•
If this is a SERVO axis and the servo is off the warning
message is set.
•
If the WatchDog is off the warning message is set.
•
If the jog speed is 0 the warning message is set.
•
If the acceleration rate on this axis is 0 the warning message is
set.
•
If the deceleration rate on this axis is 0 the warning message is
set.
I52E-EN-03.book Seite 217 Freitag, 29. Juni 2007 11:55 11