3.2.125 FORWARD
/i
3.2.126 FPGA_VERSION
/i
3.2.127 FRAC
/i
3.2.128 FRAME
/i
Type
Axis command
Syntax
FORWARD
FO
Description
The
FORWARD
command moves an axis continuously forward at the speed
set in the
SPEED
axis parameter. The acceleration rate is defined by the
ACCEL
axis parameter.
FORWARD
works on the default basis axis (set with
BASE
) unless
AXIS
is
used to specify a temporary base axis.
Note: The forward motion can be stopped by executing the
CANCEL
or
RAPIDSTOP
command, or by reaching the forward limit.
Arguments
N/A
Example
start:
FORWARD
WAIT UNTIL IN(0) = ON ' Wait for stop signal
CANCEL
See also
AXIS
,
CANCEL
,
RAPIDSTOP
,
REVERSE
,
UNITS
.
Type
Slot parameter
Syntax
FPGA_VERSION SLOT(unit_number)
Description
This parameter returns the FPGA version of unit with unit_number in a con-
troller system.
Arguments
•
unit_number
Unit numbers are -1 to 6, including 0, with -1 being the TJ1-MC__ and 0
being the unit immediately to the right of the TJ1-MC__.
Example
N/A
See also
N/A
Type
Mathematical function
Syntax
FRAC(expression)
Description
The
FRAC
function returns the fractional part of the expression.
Arguments
•
expression
Any valid BASIC expression.
Example
>> PRINT FRAC(1.234)
0.2340
See also
N/A
Type
System parameter
Syntax
FRAME=value
Description
Used to specify which frame to operate within when employing frame transfor-
mations. Frame transformations are used to allow movements to be specified
in a multi-axis coordinate frame of reference which do not correspond one-to-
one with the axes. An example is a SCARA robot arm with jointed axes. For
the end tip of the robot arm to perform straight line movements in X-Y the
motors need to move in a pattern determined by the robots geometry.
Frame transformations to perform functions such as these need to be com-
piled from C language source and loaded into the controller system software.
Contact OMRON if you need to do this.
A machine system can be specified with several different frames. The cur-
rently active
FRAME
is specified with the
FRAME
System parameter.
The default
FRAME
is 0 which corresponds to a one-to-one transformation.
Arguments
N/A
Example
FRAME=1
See also
N/A