Examples and tips
PROGRAMMING MANUAL
254
Revi
si
on 3.0
fig. 25
The figure shows a general origin search scenario. This simple
origin search sequence has 3 steps:
1. Search for a signal.
2. Search for another signal.
3. Move the axis to a predefined position.
It is important to note that, before any homing procedure is
executed, it is necessary to set the axis parameters
UNITS
,
REP_DIST
and
REP_OPTION
, and Servo Driver parameters
Pn202, Pn203 and Pn205 properly and in accordance with the
mechanical system and desired measurement units used in
programming. Those parameters have influence to the origin
search, especially if an absolute encoder is used. For more
information on setting these parameters, see section 6.1.2.
ON
min. limit switch
origin limit switch
moving part
max. limit switch
encoder
OFF
ON OFF
OFF
ON
OFF
For safety reasons, limit switches are normally closed.
For this reason, in this figure and in the following figures
in this section, the low signal level is indicated as ON, and
the high signal level is indicated as OFF.
I52E-EN-03.book Seite 254 Freitag, 29. Juni 2007 11:55 11