6-6
H
Operation Specifications
Control input
Three photocoupler input terminals (24 VDC, 8 mA)
•
Forward/stop [SF]
•
Reverse/stop [SR]
•
Multi-function input [S1] (set in constant No. 06)
Select either of “fault reset,” “external fault,” and “multi-step
speed command.”
Note When 3-wire sequence mode (constant No. 01 = “9”) is se-
lected, the terminals become as follows:
•
Run command [SF]
•
Stop command [SR]
•
Forward/reverse rotation command [S1]
One analog input terminal (0 to 10 VDC or 4 to 20 mA)
•
Frequency reference input [Between FC and FR]
Control output
One SPDT relay contact output terminal [MA, MB]
(30 VDC and 1A; 250 VAC and 1A)
•
Multi-function contact output (set in constant No. 09)
Select either of “fault occurrence,” “operation in progress,” and
“frequency matching.”
Specifications
Chapter 6
Содержание SYSDRIVE 3G3EV SERIES
Страница 1: ...USER S MANUAL SYSDRIVE 3G3EV Standard Models Compact Low noise Inverter Cat No I011 E1 3...
Страница 5: ...Chapter 1 Getting Started 1 1 Items to be Checked when Unpacking 1 2 Precautions 1...
Страница 9: ...Chapter 2 Overview 2 1 Features 2 2 Component Names 2...
Страница 14: ...Chapter 3 Design 3 1 Installation 3 2 Wiring 3...
Страница 32: ...Chapter 4 Preparing for Operation 4 1 Preparation Procedure 4 2 Using the Digital Operator 4 3 Test Run 4...
Страница 72: ...Chapter 6 Specifications 6 1 Specifications of Main Unit 6...