5-7
H
Data Display and Action to be Taken when Inverter Error
Occurs
The first character of an error code is always “F” when an Inverter error occurs. (Howev-
er, all indicators are not lit when a control circuit error occurs.)
If an Inverter error occurs, turn the power off, then on. If the problem persists, replace the
Unit.
Data
display
Description
Action
f00
Initial memory error
•
Turn the power off, then on.
•
f01
ROM error
•
If the problem persists, replace the
Unit.
f04
Constant error
•
Write down all the constant settings,
initialize the constants, and reset the
constants.
•
Turn the power off, then on.
•
If the problem persists, replace the
Unit.
f05
A/D converter error
•
Turn the power off, then on.
•
If the problem persists, replace the
Unit.
f06
Option error
The Digital Operator has an error or
faulty contact.
•
Turn the power off, then reinstall the
Digital Operator.
•
If the problem persists, replace the
Unit.
(Not lit)
Control circuit error
An error occurred in the control power
supply or hardware.
•
Check the power cables.
•
Replace the Unit.
Operation
Chapter 5
Содержание SYSDRIVE 3G3EV SERIES
Страница 1: ...USER S MANUAL SYSDRIVE 3G3EV Standard Models Compact Low noise Inverter Cat No I011 E1 3...
Страница 5: ...Chapter 1 Getting Started 1 1 Items to be Checked when Unpacking 1 2 Precautions 1...
Страница 9: ...Chapter 2 Overview 2 1 Features 2 2 Component Names 2...
Страница 14: ...Chapter 3 Design 3 1 Installation 3 2 Wiring 3...
Страница 32: ...Chapter 4 Preparing for Operation 4 1 Preparation Procedure 4 2 Using the Digital Operator 4 3 Test Run 4...
Страница 72: ...Chapter 6 Specifications 6 1 Specifications of Main Unit 6...