4-8
4-2-3 Setting Constants
The 3G3EV (Standard Model) allows the user to set 18 different constants.
The constants for basic operations are allocated to dedicated indicators,
so the user need not refer to the constant nos. The constants allocated to
dedicated indicators can be also set by lighting the PRGM indicator.
Note that the operation methods using dedicated indicators and the PRGM
indicator are different.
H
Setting Constants
D
Setting Constants Using a Dedicated Indicator
Example:
Changing acceleration time from 10 seconds to 50 seconds.
Key
operation
Indicator
Example of
data display
Explanation
10.0
Press the Mode Key until the ACC indicator lights
up.
Flashing
10.1
Press the Increment Key. The data display section
flashes (indicating that the data is yet to be
registered).
Flashing
50.0
Press the Increment Key until “50.0” appears in
the data display section. Holding down the key
changes data quickly.
50.0
Press the Enter Key to complete the setting
procedure.
10.0
50.0
50.0
Flashing
Note If the new data is not to be registered, press the Mode Key instead of the Enter
Key. The new data becomes invalid and the next item is displayed.
Preparing for Operation
Chapter 4
Содержание SYSDRIVE 3G3EV SERIES
Страница 1: ...USER S MANUAL SYSDRIVE 3G3EV Standard Models Compact Low noise Inverter Cat No I011 E1 3...
Страница 5: ...Chapter 1 Getting Started 1 1 Items to be Checked when Unpacking 1 2 Precautions 1...
Страница 9: ...Chapter 2 Overview 2 1 Features 2 2 Component Names 2...
Страница 14: ...Chapter 3 Design 3 1 Installation 3 2 Wiring 3...
Страница 32: ...Chapter 4 Preparing for Operation 4 1 Preparation Procedure 4 2 Using the Digital Operator 4 3 Test Run 4...
Страница 72: ...Chapter 6 Specifications 6 1 Specifications of Main Unit 6...