246
Parameter List
Appendix
Vari-
able
type
CompoWay/F
Modbus
Parameter name
Setting (monitor) range
De-
fault
Unit
Attrib-
utes
Target Unit
Category
Add-
ress
Address
TC4/
TC2
HFU
DA
(9A)
Can be
changed
during
opera-
tion.
0100
F000
G3PW1-Internal Duty Setting
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0101
F001
G3PW1-Base-up Value
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0102
F002
G3PW1-Soft-start Up Time
H' 00000000 to H' 000003E7 (0.0 to 99.9)
0.5
s
NUM
●
---
0103
F003
G3PW1-Soft-start Down Time
H' 00000000 to H' 000003E7 (0.0 to 99.9)
0.0
s
NUM
●
---
0104
F004
G3PW1-Output Upper Limit
H' 00000001 to H' 000003E8 (0.1 to 100.0)
100.0
%
NUM
●
---
0105
F005
G3PW1-Output Lower Limit
H' 00000000 to H' 000003E7 (0.0 to 99.9)
0.0
%
NUM
●
---
0106
F006
G3PW1-Heater Burnout Threshold
H' 00000000 to H' 00000064 (1 100)
100
%
NUM
●
---
0107
F007
G3PW1-Heater Characteristic Resistance for
Phase Control
H' 00000000 to H' 00000064 (1 to 100)
100
%
NUM
●
---
0108
F008
G3PW1-Heater Characteristic Resistance for
Optimum Cycle Control
H' 00000000 to H' 000003E7 (0.0 to 99.9)
0.0
W
NUM
●
---
0109
F009
G3PW1-Heater Burnout Detection Lower
Limit
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0140
F040
G3PW1-Input Monitor
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0141
F041
G3PW1-Duty Monitor
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0142
F042
G3PW1-Output Monitor
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0143
F043
G3PW1-Phase Angle Monitor
H' 00000000 H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
0144
F044
G3PW1-Current Monitor
H' 00000000 to H' 000002EE (0.0 to 75.0)
0.0
A
NUM
●
---
0145
F045
G3PW1-Total Run Time Monitor
H' 00000000 to H' 000003E7 (0.0 to 99.9)
0.0
kh
NUM
●
---
0146
F046
G3PW1-Status
---
---
---
NUM
●
---
0154
F054
Version
---
---
---
NUM
●
---
0180
F080
G3PW1-Send Wait Time
H' 00000000 to H' 00000063 (0 to 99)
1
ms
NUM
●
---
0181
F081
G3PW1-Communications Timeout Time
H' 00000000 to H' 000003E7 (0 to 999)
0
s
NUM
●
---
0184
F084
G3PW1-Communications Main Setting Num-
ber
H'00000000: Automatic Assignment (0)
H'00000001: EJ1 CH1 Control output (heating) (1)
H'00000002: EJ1 CH2 Control output (heating) (2)
H'00000003: EJ1 CH3 Control output (heating) (3)
H'00000004: EJ1 CH4 Control output (heating) (4)
H'00000005: EJ1 CH1 Control output (cooling) (5)
H'00000006: EJ1 CH2 Control output (cooling) (6)
H'00000007: EJ1 CH3 Control output (cooling) (7)
H'00000008: EJ1 CH4 Control output (cooling) (8)
0
---
NUM
●
---
0185
F085
G3PW1-External Duty Input Enable/Disable
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
0
---
NUM
●
---
0186
F086
G3PW1-Output Mode Selection
H' 00000000: Proportional to Phase Angle
(for G3PX Compatibility) (0)
H' 00000001: Proportional to Square Voltage (1)
H' 00000002: Proportional to Voltage (2)
H' 00000003: Constant Current (3)
0
---
NUM
●
---
0187
F087
G3PW1-Input Digital Filter Time Constant
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
ms
NUM
●
---
0188
F088
G3PW1-Input Signal Type
H' 00000000: Linear Input (0)
H' 00000001: Voltage ON/OFF Input (1)
0
---
NUM
●
---
0189
F089
G3PW1-Main Setting Automatic Input Selec-
tion
H' 00000000: 4 to 20 mA or 1 to 5 V (0)
H' 00000001: Communications (1)
0
---
NUM
●
---
018A
F08A
G3PW1-Main Setting Manual Input Selection
H' 00000000: External Adjuster Input (0)
H' 00000001: Key Input (1)
0
---
NUM
●
---
018B
F08B
G3PW1-Control Method Default
H' 00000000: Phase Control (0)
H' 00000001: Optimum cycle control (1)
0
---
NUM
●
---
018C
F08C
G3PW1-Main Setting Automatic/Manual
Default
H' 00000000: Automatic (0)
H' 00000001: Manual (1)
0
---
NUM
●
---
018D
F08D
G3PW1-Number of Alarms for Heater Burnout
Detection
H' 00000000 to H' 000003E7 (0 to 999)
150
Times
NUM
●
---
018E
F08E
G3PW1-Load Current Upper Limit
H' 00000000 to H' 00000294 (0.0 to 66.0)
0.0
A
NUM
●
---
018F
F08F
G3PW1-Event Input Assignment
H' 00000000: No Assignment (0)
H' 00000001: Control Method Selection (1)
H' 00000002: Main Setting Automatic/Manual
Selection (2)
0
---
NUM
●
---
0190
F090
G3PW1-Alarm Output Open in Alarm
H' 00000000: Close in alarm (0)
H' 00000001: Open in alarm (1)
1
---
NUM
●
---
0191
F091
G3PW1-Heater Burnout Alarm Operation
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
0
---
NUM
●
---
0192
F092
G3PW1-Total Run Time Exceeded Alarm
Operation
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
0
---
NUM
●
---
0193
F093
G3PW1-Total Run Time Alarm Set Value
H' 00000000 to H' 000003E7 (0 to 99.9)
0.0
kh
NUM
●
---
0194
F094
G3PW1-External Input Range Alarm Opera-
tion
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
1
---
NUM
●
---
0195
F095
G3PW1-External Duty Input Alarm Operation
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
1
---
NUM
●
---
Not used.
0200
F100
G3PW2 - Internal Duty Setting
The rest are the same as the G3PW1.
···
···
···
0300
F200
G3PW3 - Internal Duty Setting
···
···
···
0400
F300
G3PW4 - Internal Duty Setting
V1.1
Содержание EJ1 EtherCAT
Страница 2: ...EJ1 Modular Temperature Controllers User s Manual Revised July 2008 ...
Страница 3: ...iv ...
Страница 19: ...xx ...
Страница 213: ...188 Detailed Description of Services Section 6 4 ...
Страница 227: ...202 Detailed Description of Services Section 7 5 ...
Страница 251: ...226 Determining the Error from the Current Situation for Heater Burnout Alarm Errors Section 8 8 ...
Страница 303: ...278 Index ...
Страница 305: ......