182
Detailed Description of Services
Section 6-4
6-4-9
Controller Status Read
This service reads the operating status and error status.
■
Command
Service Request PDU
■
Response
Service Response PDU
1.
Operating Status
• TC4/TC2
• HFU
Fixed to 00.
2.
Related Status
3.
Response Codes
MRC
2
0
6
SRC
2
1
0
Channel
Bit position
Meaning
CH1
0
00: Operating
01: Error output
10: Stopped
11: In manual operation
1
CH2
2
3
CH3
4
5
CH4
6
7
Code
HFU
TC4 and TC2
00
Startup processing
Startup processing
01
Device failure
Device failure
02
Device error
Device error
03
Configuration confirmation
Configuration confirmation
04
Configuration error
Configuration error
05
---
---
06
Normal
Normal
Response code
Error name
Cause
1001
Command too long
The command is too long.
0000
Normal completion
Processing was completed normally.
MRC
2
0
6
SRC
2
1
0
4
2
2
Response
code
Operating
status
Related
Informa-
tion