268
Parameters That Can Be Allocated for Programless Communications
Appendix
Parameters That Can Be Allocated for Programless
Communications
The following table lists the parameters that can be allocated to programless communications.
Function
Parameter
Attribute
Upload
Download
Remarks
Status
Device A Status
Common
●
---
Monitoring only
Device Error Status
Common
●
---
Monitoring only
Configuration Error A Status
Common
●
---
Monitoring only
Configuration Error B Status
Common
●
---
Monitoring only
Internal Communications Error Status
Common
●
---
Monitoring only
I/O Error Status
Common
●
---
Monitoring only
I/O Alarm A Status
Common
●
---
Monitoring only
I/O Alarm B Status
Common
●
---
Monitoring only
I/O Notification A Status
Common
●
---
Monitoring only
Error Channel A Status
Common
●
---
Monitoring only
Basic Unit/Expand Unit Error
Common
●
---
Monitoring only
Basic Unit/Expand Unit Alarm
Common
●
---
Monitoring only
Output Status
Common
●
---
Monitoring only
Device B Status
Common
●
---
Monitoring only
HB Alarm
Heater Current Value 1 Monitor
IO
●
---
Monitoring only
Leakage Current Value 1 Monitor
IO
●
---
Monitoring only
Heater Current Value 2 Monitor
IO
●
---
Monitoring only
Leakage Current Value 2 Monitor
IO
●
---
Monitoring only
Heater Burnout 1 Detection
IO
●
●
HS Alarm 1
IO
●
●
Heater Overcurrent 1 Detection
IO
●
●
Heater Burnout 2 Detection
IO
●
●
HS Alarm 2
IO
●
●
Heater Overcurrent 2 Detection
IO
●
●
Monitoring
Process Value
CH
●
---
Monitoring only
Channel Status
CH
●
---
Monitoring only
Channel Alarm Status
CH
●
---
Monitoring only
Internal SP
CH
●
---
Monitoring only
Local SP Monitor
CH
●
---
Monitoring only
Remote SP Monitor
CH
●
---
Monitoring only
Bank No. Monitor
CH
●
---
Monitoring only
MV Monitor (Heating)
CH
●
---
Monitoring only
MV Monitor (Cooling)
CH
●
---
Monitoring only
Decimal Point Monitor
CH
●
---
Monitoring only
Target value
Present Bank Set Point
BANK
●
●
Present Bank SP Ramp Rise Value
BANK
●
●
Present Bank SP Ramp Fall Value
BANK
●
●
SP Upper Limit
CH
●
●
SP Lower Limit
CH
●
●
Alarms
Present Bank Alarm Value 1
BANK
●
●
Present Bank Alarm Upper Limit Value 1
BANK
●
●
Present Bank Alarm Lower Limit Value 1
BANK
●
●
Present Bank Alarm Value 2
BANK
●
●
Present Bank Alarm Upper Limit Value 2
BANK
●
●
Present Bank Alarm Lower Limit Value 2
BANK
●
●
Present Bank Alarm Value 3
BANK
●
●
Present Bank Alarm Upper Limit Value 3
BANK
●
●
Present Bank Alarm Lower Limit Value 3
BANK
●
●
Inputs
Input Digital Filter
CH
●
●
Input Value 1 for Input Correction
CH
●
●
Input Shift 1
CH
●
●
Input Value 2 for Input Correction
CH
●
●
Input Shift 2
CH
●
●
Содержание EJ1 EtherCAT
Страница 2: ...EJ1 Modular Temperature Controllers User s Manual Revised July 2008 ...
Страница 3: ...iv ...
Страница 19: ...xx ...
Страница 213: ...188 Detailed Description of Services Section 6 4 ...
Страница 227: ...202 Detailed Description of Services Section 7 5 ...
Страница 251: ...226 Determining the Error from the Current Situation for Heater Burnout Alarm Errors Section 8 8 ...
Страница 303: ...278 Index ...
Страница 305: ......